Dehn, BVT Surge Protector 35V dc Maximum Voltage Rating 2 kA Maximum Surge Current Lightning Arrester

Bulkkorting beschikbaar
Bekijk bulkkorting

Subtotaal (1 eenheid)*

€ 506,26

(excl. BTW)

€ 612,57

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.

Aantal stuks
Per stuk
1 - 1€ 506,26
2 - 4€ 486,00
5 +€ 460,69

*prijsindicatie

RS-stocknr.:
768-1851
Fabrikantnummer:
BVT AD 24
Fabrikant:
Dehn
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Dehn

Suppressor Type

Lightning Arrester

Product Type

Surge Protector

Maximum Voltage

35V dc

Mount Type

DIN Rail

Maximum Surge Current

2kA

Series

BVT

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

80°C

Standards/Approvals

UL, CSA, GOST, RoHS

Depth

58mm

Height

90mm

Length

27mm

Hazardous Area Certification

No

DEHN Data Signal Surge Arresters


DEHN data signal surge arresters for industrial process control circuits, the protection of the low voltage power supply and the I/O of PLC applications using sensors and transducers.

Combined lightning current and surge arresters for signal and data lines with one base design common to all Yellow line plugs

Activsense technology automatically detects the signal voltage from 0 to 180v and adapts the voltage protection level for optimal performance

Integrated LifeCheck monitoring function ensuring highest availability and rapid detection of damaged arrestors

Power protection unit for PLC DC power supply systems in a slim DIN housing

Surge Protection Devices, SPDs (DIN-rail)


Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.