Signal Conditioners | RS
Log in / Registreer om gebruik te maken van uw voordelen
Onlangs gezocht

    Signal Conditioners

    Signal conditioners are electronic devices used to modify and optimize electrical signals in various measurement and control systems. They are typically employed in situations where the electrical signals from sensors, transducers, or other sources need to be adjusted or conditioned to meet specific requirements.

    How do Signal Conditioners Work?

    The primary purpose of a signal conditioner is to ensure that the signals are suitable for further processing, transmission, or conversion by other devices or systems. Signal conditioners can perform a variety of functions depending on the specific application.

    What are the types of Signal Conditioning?

    Signal conditioners can be classified into several types based on their specific functions and the signals they process. Here are some common types of signal conditioners: Amplifiers: Amplifiers are signal conditioners used to amplify weak input signals. They increase the signal strength to a level suitable for further processing or transmission. Filters: Signal conditioners that incorporate filters are used to remove unwanted noise or interference from the input signals. Different types of filters, such as low-pass, high-pass, band-pass, or notch filters, are used based on the specific frequency ranges to be filtered. Linearizers: Linearizers are signal conditioners that compensate for nonlinearities in the input signal. They apply mathematical algorithms or lookup tables to linearize the output and provide a more linear response over the measurement range. Isolation Amplifiers: These signal conditioners provide electrical isolation between the input and output sides of a system. They protect sensitive measurement equipment from electrical noise, voltage spikes, and ground loops, ensuring accurate and reliable measurements. Converters: Signal conditioners known as converters are used to convert signals from one form to another. For example, analogue-to-digital converters (ADCs) convert analogue signals into digital form, while digital-to-analogue converters (DACs) convert digital signals into analogue form.

    Where are Signal Conditioners Used?

    Signal conditioners are widely used in industrial automation, process control, data acquisition systems, scientific research, and various other fields where accurate and reliable signal processing is essential. They play a crucial role in optimizing signal quality, reducing noise, and improving the overall performance of measurement and control systems.

    655 Producten voor Signal Conditioners

    Pepperl + Fuchs
    -
    Temperature Converter
    RTD, Potentiometer, Thermocouple, Voltage
    -
    Current, Voltage
    -
    (Resistor) 0 → 5 kΩ, (Potentiometer) 0.2 → 50 kΩ, (PTC) -100 → +100 mV, -1000 → +1000 mV, (RTD) 200µA
    0 → 10 mA, 0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 mA, 2 → 10 V, 4 → 20mA
    16.8 → 31.2V dc
    -
    DIN Rail Mount
    -
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    S1SD
    Crouzet
    -
    Temperature Converter
    Thermocouple
    -
    Voltage
    -
    0 → 600°C
    0 → 10V dc
    24V dc
    -
    DIN Rail Mount
    -
    -5°C
    -5 → +55°C
    +55°C
    -
    -
    -
    Red Lion Controls
    -
    Frequency to Analogue Converter
    -
    -
    Analogue, Relay
    -
    -
    -
    21.6 → 25V ac
    -
    -
    -
    -
    -
    -
    -
    -
    IFM
    Phoenix Contact
    -
    Communication Module
    Current
    -
    -
    -
    4 → 20mA
    -
    12 → 24V dc
    -
    DIN Rail Mount
    -
    -40°C
    -40 → +55°C
    +55°C
    -
    -
    MINI MCR
    WAGO
    -
    Signal Conditioner
    Current, Voltage
    -
    Current, Voltage
    -
    0 → 1kΩ
    0 → 5 V, 0 → 10 V, 1 → 5 V, 2 → 10 V
    24V dc
    -
    DIN Rail
    -
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    857
    Phoenix Contact
    -
    Signal Conditioner
    Voltage
    -
    Voltage
    -
    0 → 10V dc
    0 → 11V
    9.6 → 30V dc
    ATEX
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    GEORGIN
    -
    -
    Current
    -
    Analogue
    -
    4 → 20mA
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    GH 11000
    Weidmüller
    -
    Current Measuring Transducer
    -
    -
    Analogue
    -
    -
    0 → 10V
    24V
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Weidmüller
    -
    Signal Converter
    Current
    -
    Analogue
    -
    4 → 20mA
    4 → 20mA
    -
    ATEX, IECEx
    -
    -
    -
    -
    -
    -
    -
    ACT20M
    Jumo
    -
    Conductivity Transmitter
    Conductivity, Temperature
    -
    Current, Voltage
    -
    -10 → +150°C
    0 → 10 V, 0 → 20mA
    20 → 30V dc
    -
    DIN Rail Mount
    -
    -10°C
    -10 → +60°C
    +60°C
    -
    -
    ecoTRANS
    WAGO
    -
    Isolating Amplifier
    Current
    -
    Voltage
    -
    40 → 20mA
    0 - 10V dc
    24V dc
    -
    -
    -
    -
    -
    -
    -
    -
    857
    WAGO
    -
    Current Transducer
    Current
    -
    Digital, Relay
    -
    (DC) -100 → 100 A, (AC) 500 mA → 100A
    ± 10 V, ± 20mA
    24V dc
    -
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    -
    Weidmüller
    -
    Resistance Temperature Device Input Converter
    RTD
    -
    Current
    -
    -50 → 150°C
    4 → 20mA
    9 → 30V dc
    -
    DIN Rail Mount
    -
    0°C
    0 → +50°C
    +50°C
    -
    -
    ACT20X
    Weidmüller
    -
    Signal Isolator
    Current, Voltage
    -
    Current, Voltage
    -
    0 → 10 V, 0 → 20mA
    0 → 10 V, 0 → 20mA
    24V dc
    -
    DIN Rail Mount
    -
    0°C
    0 → +55°C
    +55°C
    -
    -
    ACT20X
    Phoenix Contact
    -
    Signal Duplicator
    Current, Voltage
    -
    Current, Voltage
    -
    0 → 12 V, 0 → 24mA
    0 → 10.5 V, 0 → 21mA
    24V dc
    ATEX
    DIN Rail Mount
    -
    -40°C
    -40 → +70°C
    +70°C
    -
    -
    MINI MCR
    Weidmüller
    -
    Isolation Amplifier
    NAMUR Sensor, Switch
    -
    NPN Open Collector
    -
    8V dc
    <2.5V dc
    19.2 → 31.2V
    IECEx
    DIN Rail Mount
    -
    -20°C
    -20 → +60°C
    +60°C
    -
    -
    ACT20X
    Phoenix Contact
    -
    Resistance/Potiposition Transducer
    Resistance
    -
    Current, Voltage
    -
    100 → 100000 Ω
    0 → 10 V, 0 → 20mA
    24V dc
    ATEX
    DIN Rail Mount
    -
    -20°C
    -20 → +65°C
    +65°C
    -
    -
    MINI MCR
    Weidmüller
    -
    Temperature Converter
    RTD
    -
    Current, Relay
    -
    -200 → +850°C
    0 → 20 mA, 4 → 20mA
    230 V ac, 24 → 230V dc
    -
    -
    -
    -25°C
    -25 → +75°C
    +70°C
    -
    -
    ACT20P
    WAGO
    -
    Isolation Amplifier
    Current, Voltage
    -
    Current
    -
    0 → 10 V, 0 → 20 mA, 0 → 5 V, 1 → 5 V, 2 → 10 V, 4 → 20mA
    0 → 20 mA, 4 → 20mA
    24V dc
    ATEX, IECEx
    DIN Rail Mount
    -
    -25°C
    -25 → +70°C
    +70°C
    -
    -
    JUMPFLEX
    Novotechnik
    -
    Signal Conditioner
    -
    -
    -
    -
    0 → 10V
    4 → 20mA
    -
    -
    -
    -
    -
    -
    -
    -
    -
    Series MUW 200
    Resultaten per pagina