ABB Auxiliary Contact, 2 Contact, 2 NO, CAF6-20M, Front, 6 A, 240 V dc, 500V ac, GJL1201330R0007 CAF6-20M

Subtotaal (1 eenheid)*

€ 15,28

(excl. BTW)

€ 18,49

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 11 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 15,28

*prijsindicatie

RS-stocknr.:
445-8273
Fabrikantnummer:
GJL1201330R0007 CAF6-20M
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Auxiliary Contact

Number of Contacts

2

Normal State Configuration

2 NO

Series

CAF6-20M

Mount Type

Front

Contact Current

6A

Terminal Type

Screw

Pole and Throw Configuration

2P

Contact Voltage

240, 500V dc

Operational Current Ie

6A

Minimum Operating Temperature

-25°C

Rated Insulation Voltage Ui

690V

Mounting Location

Front Side

Maximum Operating Temperature

55°C

Standards/Approvals

IEC/EN 60947-5-1, UL 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, IEC/EN 60947-1

Vrijgesteld

ABB CAF6-20M Series Auxiliary Contact, 6A Contact Current, 690V Rated Insulation Voltage - GJL1201330R0007 CAF6-20M


This auxiliary contact is a front-mount add-on designed to provide two normally open auxiliary contacts for control and signalling tasks in electrical installations. It connects directly to compatible mini contactors to extend switching logic and status feedback in automation and electrical panels, operating across DC and AC auxiliary circuits.

Features & Benefits


• 2NO 2P configuration delivers simple contact expansion
• Rated insulation 690V ensures high-voltage separation
• Operational current 4A enables reliable control-circuit switching
• Conventional thermal current 6A supports steady auxiliary loads
• Screw terminals provide secure conductor fixation
• Tightening torque 0.8 to 1.1N·m gives consistent contact pressure

**Applications**


• Suitable for extending control contacts on mini contactors
• Used with motor control circuits requiring front-mounted auxiliaries
• Ideal for status signalling to PLCs and monitoring equipment
• Suitable for retrofit auxiliary functionality in distribution panels
• Used for interlock logic in machine-control cabinets

What wire sizes can be terminated into the contact block?


The terminals accept flexible conductors with ferrules 1/2x1 to 2.5mm², flexible conductors 1/2x1 to 2.5mm² and rigid conductors 1/2x1 to 4mm².

What environmental limits should be observed during installation?


The unit is rated for operation between -25 to +55°C and may be stored between -40 to +80°C

maximum operating altitude is 2000 m.

Which electrical standards does it conform to for industrial use?


It meets IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1 and corresponding UL equivalents.

How does the product perform under mechanical stress?


It withstands shock pulses of 11 MS at 15 g and vibration levels of 5 g across 5 to 150 Hz as per IEC 60068 tests.

What torque and stripping preparations are required for reliable connections?


Use a torque of 0.8 to 1.1 N·m and a wire stripping length of 9mm for proper termination.