ABB Auxiliary Contact, 4 Contact, 4 NO, CA4, Front, 6 A, 600 V dc, 690V ac, 1SBN010140R1040 CA4-40E

Subtotaal (1 eenheid)*

€ 26,36

(excl. BTW)

€ 31,90

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 35 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 26,36

*prijsindicatie

RS-stocknr.:
711-6345
Fabrikantnummer:
1SBN010140R1040 CA4-40E
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Number of Contacts

4

Product Type

Auxiliary Contact

Normal State Configuration

4 NO

Series

CA4

Contact Current

6A

Mount Type

Front

Terminal Type

Screw

Pole and Throw Configuration

4

Contact Voltage

600V dc, 690V dc

Rated Insulation Voltage Ui

690V

Mechanical Durability

10Mcycles

Mounting Location

Front Side

Minimum Operating Temperature

-40°C

Operational Current Ie

6A

Maximum Operating Temperature

70°C

Standards/Approvals

No

ABB CA4 Series Auxiliary Contact, 6A Contact Current, 690V Contact Voltage - 1SBN010140R1040 CA4-40E


This auxiliary contact is a front-mounted, four-pole add-on intended to expand the switching information available from a contactor. It provides instantaneous normally open contacts for signalling and interlocking in industrial control panels and machinery, and is designed for use with compatible contactors to deliver additional auxiliary switching functions in automation and electrical installations.

Features & Benefits


• Four N.O. contacts delivering clear switching indication
• Rated insulation voltage 690V for high-voltage auxiliary circuits
• Operational current 6A enabling control and signalling loads
• Mechanical endurance 10M cycles for long service intervals
• Operating temperature range -40°C to 70°C for harsh environments
• Screw terminals support secure conductor connections

**Applications**


• Suitable for adding status feedback to motor contactors
• Ideal for control-panel interlocks and safety circuits
• Used with AF and AFC contactor frames requiring front-mounted blocks
• Can be used for auxiliary signalling in industrial automation racks

How are conductors terminated for reliable connections?


Connections use screw terminals sized to accept flexible and solid conductors up to 2.5mm² and ferrules where applicable, with a recommended wire strip length of 10mm.

What electrical endurance can be expected under normal thermal conditions?


The conventional free-air thermal current is 16A at 40°C according to IEC 60947-5-1, indicating the Block withstands expected thermal loads in control circuits.

What short-time withstand capability does it offer for fault conditions?


It has rated short-time withstand currents of 140A for 0.1s and 100A for 1s for AC-15 duties, supporting brief fault or inrush scenarios.

Which protection and certifications apply to its terminals and construction?


Auxiliary terminals are rated to IP20 and the unit carries multiple conformity declarations and certificates relevant to low-voltage control products.

Standards

UL 508, CSA C22.2 N14

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.