Schneider Electric 415V DIN Rail Circuit Trip for use with Ild Double Terminal, ARA, RCA, ISW-NA, IDPN Vigi, IlD MCB,

Subtotaal (1 eenheid)*

€ 66,37

(excl. BTW)

€ 80,31

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 45 stuk(s) vanaf 23 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 66,37

*prijsindicatie

RS-stocknr.:
791-2815
Fabrikantnummer:
A9A26946
Fabrikant:
Schneider Electric
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schneider Electric

Range

Acti9

Product Type

Circuit Trip

Series

iMX

For Use With

Ild Double Terminal, ARA, RCA, ISW-NA, IDPN Vigi, IlD MCB, iC60 MCB

Mount Type

DIN Rail

Terminal Type

Clamp

Standards/Approvals

EN/IEC 60947-5-1

Control Voltage

415V

Schneider Electric A9A Series Circuit Trip, 100VAC to 415VAC AC Voltage Range - A9A26946


This circuit trip is a shunt trip release designed to provide remote tripping of breakers in AC and DC control circuits. It integrates an auxiliary overcurrent contact and is configured for clip-on mounting on DIN-rail supports, offering simple addition to compatible modular protection devices within industrial distribution panels.

Features & Benefits


• Operates from 100 to 415VAC and 110 to 130VDC for flexible control
• One changeover signal contact providing secure status indication
• Rated AC switching capacities of up to 6A at relevant voltages for auxiliary loads
• 18mm width enables dense distribution panel layouts
• Clamp terminals accepting up to 6mm² rigid conductors for robust connections

Applications


• Suitable for remote tripping of MCCB and RCBO protection devices
• Used with Acti9 iC60 and iKQE modular protective units
• Ideal for retrofit installations on DIN-rail distribution boards
• Used for coordinated surge and fault isolation in control circuits

What control voltages will operate the unit?


It accepts AC control voltages from 100 to 415VAC at 50/60Hz and DC control voltages from 110 to 130V.

How is the unit mounted and connected within a distribution board?


The module clips onto a standard DIN rail and uses clamp terminals that accept up to 6mm² rigid or 4mm² flexible conductors with a 1N.m tightening torque.

What signalling is available to confirm actuation?


Local indication is provided via an action indicator and a single changeover contact for remote status monitoring.

Which standards govern the device’s electrical and safety characteristics?


It is designed to comply with EN/IEC 60947-1 and EN/IEC 60947-5-1 requirements.

How should end users manage disposal on EU markets?


The unit must be handled under WEEE requirements and disposed of via appropriate collection schemes rather than landfill.