Eaton DILMS Contactor, 240V ac Coil, 3-Pole, 25 A, 11 kW 230V ac, 3 NO, 400V ac
- RS-stocknr.:
- 187-5353
- Fabrikantnummer:
- 191758 DILMS25-R23(230V50HZ,240V60HZ)
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 145,44
(excl. BTW)
€ 175,98
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 30 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 145,44 |
*prijsindicatie
- RS-stocknr.:
- 187-5353
- Fabrikantnummer:
- 191758 DILMS25-R23(230V50HZ,240V60HZ)
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Product Type | Contactor | |
| Coil Voltage | 240V ac | |
| Number of Poles | 3 | |
| Contact Voltage | 400V ac | |
| Contact Current | 25A | |
| Power Rating | 11kW | |
| Series | DILMS | |
| Mount Type | Table | |
| Function | Motor Control | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 5 | |
| Auxiliary Contact Configuration | 2 NO/3 NC | |
| Terminal Type | Screw Clamp | |
| Operational Current Ie | 25A | |
| Contactor Application | Safety | |
| Minimum Operating Temperature | -25°C | |
| Control Circuit Voltage Uc | 230V ac | |
| Maximum Operating Temperature | 60°C | |
| Depth | 85mm | |
| Standards/Approvals | CSA, IEC, UL | |
| Length | 56mm | |
| Width | 138mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Product Type Contactor | ||
Coil Voltage 240V ac | ||
Number of Poles 3 | ||
Contact Voltage 400V ac | ||
Contact Current 25A | ||
Power Rating 11kW | ||
Series DILMS | ||
Mount Type Table | ||
Function Motor Control | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 5 | ||
Auxiliary Contact Configuration 2 NO/3 NC | ||
Terminal Type Screw Clamp | ||
Operational Current Ie 25A | ||
Contactor Application Safety | ||
Minimum Operating Temperature -25°C | ||
Control Circuit Voltage Uc 230V ac | ||
Maximum Operating Temperature 60°C | ||
Depth 85mm | ||
Standards/Approvals CSA, IEC, UL | ||
Length 56mm | ||
Width 138mm | ||
Pole and Throw Configuration 3P | ||
Vrijgesteld
The Eaton DLIMS series safety contactors offer reliable switching in safety-related device applications. This contactor has a yellow cover to allow for fast and efficient identification of your safety devices. The dependable design of this contactor provides the perfect solution for the protection of your devices from manual activation. As standard, all versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact, to stop tampering and prevent manual actuation this is non-detachable.
Safe status monitoring of the contactor manual activation is not possible
Eligible to be used for Emergency-stop application with controlled start
Reliable and self-monitoring machine-control circuits
Interlocking opposing contacts
Mirror contacts
Highlighted in yellow
Reliable screw terminals
Top-mounted and non-detachable auxiliary contact
Eaton DLIMS Series Safety Contactors
The DILMS series of safety contactors from Eaton offer reliable switching in safety-related device applications.
As standard, all versions of the DILMS safety contactor are equipped with a top-mounted auxiliary contact, to stop tampering and prevent manual actuation this is non-detachable. For added safety, this contactor has integrated mirror contacts and interlocking opposite contacts.
With a built-in inspection window placed immediately above the switch position indicator, it's easy to monitor the operating status of your control systems at all times. This contactor has a yellow cover to allow for fast and efficient identification of your safety devices. The dependable design of this contactor provides the perfect solution for the protection of your devices from manual activation.
Available in four sizes the DILMS range of contactors cover a power range between 7 and 150 A. This series also features the DILAS safety relays which are available in three different coil voltages to complete your safety system.
Features and Benefits
• Safe status monitoring of the contactor (inspection window) manual activation is not possible
• Eligible to be used for Emergency-stop application with controlled start (category 4)
• Reliable and self-monitoring machine-control circuits
• Interlocking opposing contacts
• Mirror contacts
• Highlighted in yellow (RAL1004)
• Reliable screw terminals
• Top-mounted and non-detachable auxiliary contact (at the front)
Typical Applications
Contactors can be used across a multitude of applications, users will commonly find these contactors being used within industrial settings such as factory automation and control, railway transportation, electrical systems, electric motor, lighting, and mechanical engineering and are a key component when safety functions and the protection of equipment and users are a requirement.
Is a Safety Contactor or Safety Relay required?
When deciding whether to use a contactor or a relay for a safety circuit there are some general rules to help make the decision easier. A contactor should be used when the current is 9A or more, up to 1000 V ac and can be used for 1 or 3 phase safety applications. A relay should be used when the current is 10A or less, up to 250 V ac and usually on single-phase safety applications.
Note
Eaton formerly known as Moeller
