ABB GA75 Contactor, 220V, 230 V Coil, 3-Pole, 100 A 220V, 230 V, 3 NO, 1kV

Subtotaal (1 eenheid)*

€ 674,78

(excl. BTW)

€ 816,48

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 16 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 674,78

*prijsindicatie

RS-stocknr.:
253-2035
Fabrikantnummer:
1SBL411025R8000
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Product Type

Contactor

Coil Voltage

220, 230V

Number of Poles

3

Contact Voltage

1kV

Contact Current

100A

Series

GA75

Function

DC Switching

Normal State Configuration

3 NO

Number of Auxiliary Contacts

0

Terminal Type

Screw

Contactor Application

Control Unit

Minimum Operating Temperature

-40°C

Operational Current Ie

120A

Control Circuit Voltage Uc

220, 230V

Maximum Operating Temperature

70°C

Standards/Approvals

EU Directive 2011/65/EU RoHS Status

Width

70mm

Depth

132mm

Length

108mm

Pole and Throw Configuration

1P

Land van herkomst:
BG

ABB GA75 Series Contactor, 125A Contact Current, 220 to 230V Control Circuit Voltage - 1SBL411025R8000


This contactor is a DC switching device designed for industrial control applications where reliable opening and closing of DC circuits is required. It operates with an AC control Coil and is configured as a three-pole, single-pole connection device with three normally open contacts. The unit is intended for integration into power control assemblies and offers robust electrical switching capability for medium to high DC voltages up to 1000 V.

Features & Benefits


• Rated for continuous DC switching at 125A providing high-current handling
• AC Coil rated 220 to 230V enabling standard mains control
• Screw terminals support heavy conductors for secure connections
• Arc chutes with permanent magnets reduce DC breaking stress
• Mechanical endurance of 10 million cycles for long service life

Applications


• Suitable for DC power distribution switching in industrial plants
• Ideal for traction or battery system switching solutions
• Used for control of DC motors and large resistive loads
• Can be used in renewable energy storage and inverter protection

What Terminal types are provided for main connections?


Main poles use screw terminals with M6 screws and a 13x10mm connector option for reliable conductor clamping and high-current capacity.

How does Coil consumption affect control panel design?


Pull-in and holding values vary by frequency

pull-in around 180 to 190 V·A and holding approximately 18 to 21 V·A, which informs relay or driver sising and thermal loading in the control supply.

What environmental limits should be observed during installation?


Operate between −40 °C and +70 °C at nominal control voltage, with storage down to −60 °C and permitted altitude up to 3000 m

these conditions influence placement and enclosure selection.

How quickly does it switch under normal conditions?


Typical operate times are 8 to 27 MS to close and 4 to 11 MS to open, which assists coordination with protection devices and timing-sensitive control schemes.

Gerelateerde Links

Wees als eerste op de hoogte van onze nieuwste producten en aanbiedingen

E-mailadres

De persoonlijke gegevens die u aan ons verstrekt bij het aanmelden voor deze mailinglijst worden verwerkt in overeenstemming met ons privacybeleid.