ABB 1SBL41 Contactor, 220V, 230 V Coil, 3-Pole, 100 A 220V, 230 V, 3 NO, 1kV
- RS-stocknr.:
- 253-2035
- Fabrikantnummer:
- 1SBL411025R8000
- Fabrikant:
- ABB
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 253-2035
- Fabrikantnummer:
- 1SBL411025R8000
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 220V, 230V | |
| Number of Poles | 3 | |
| Contact Voltage | 1kV | |
| Contact Current | 100A | |
| Series | 1SBL41 | |
| Function | Control Unit | |
| Normal State Configuration | 3 NO | |
| Number of Auxiliary Contacts | 0 | |
| Terminal Type | Screw | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 220V, 230V | |
| Minimum Operating Temperature | -40°C | |
| Operational Current Ie | 120A | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | EU Directive 2011/65/EU RoHS Status | |
| Length | 108mm | |
| Depth | 132mm | |
| Width | 70mm | |
| Pole and Throw Configuration | 1P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor | ||
Coil Voltage 220V, 230V | ||
Number of Poles 3 | ||
Contact Voltage 1kV | ||
Contact Current 100A | ||
Series 1SBL41 | ||
Function Control Unit | ||
Normal State Configuration 3 NO | ||
Number of Auxiliary Contacts 0 | ||
Terminal Type Screw | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 220V, 230V | ||
Minimum Operating Temperature -40°C | ||
Operational Current Ie 120A | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals EU Directive 2011/65/EU RoHS Status | ||
Length 108mm | ||
Depth 132mm | ||
Width 70mm | ||
Pole and Throw Configuration 1P | ||
- Land van herkomst:
- BG
ABB GA75 Series Contactor, 125A Contact Current, 220 to 230V Control Circuit Voltage - 1SBL411025R8000
This contactor is a DC switching device designed for industrial control applications where reliable opening and closing of DC circuits is required. It operates with an AC control Coil and is configured as a three-pole, single-pole connection device with three normally open contacts. The unit is intended for integration into power control assemblies and offers robust electrical switching capability for medium to high DC voltages up to 1000 V.
Features & Benefits
• Rated for continuous DC switching at 125A providing high-current handling
• AC Coil rated 220 to 230V enabling standard mains control
• Screw terminals support heavy conductors for secure connections
• Arc chutes with permanent magnets reduce DC breaking stress
• Mechanical endurance of 10 million cycles for long service life
• AC Coil rated 220 to 230V enabling standard mains control
• Screw terminals support heavy conductors for secure connections
• Arc chutes with permanent magnets reduce DC breaking stress
• Mechanical endurance of 10 million cycles for long service life
Applications
• Suitable for DC power distribution switching in industrial plants
• Ideal for traction or battery system switching solutions
• Used for control of DC motors and large resistive loads
• Can be used in renewable energy storage and inverter protection
• Ideal for traction or battery system switching solutions
• Used for control of DC motors and large resistive loads
• Can be used in renewable energy storage and inverter protection
What Terminal types are provided for main connections?
Main poles use screw terminals with M6 screws and a 13x10mm connector option for reliable conductor clamping and high-current capacity.
How does Coil consumption affect control panel design?
Pull-in and holding values vary by frequency
pull-in around 180 to 190 V·A and holding approximately 18 to 21 V·A, which informs relay or driver sising and thermal loading in the control supply.
What environmental limits should be observed during installation?
Operate between −40 °C and +70 °C at nominal control voltage, with storage down to −60 °C and permitted altitude up to 3000 m
these conditions influence placement and enclosure selection.
How quickly does it switch under normal conditions?
Typical operate times are 8 to 27 MS to close and 4 to 11 MS to open, which assists coordination with protection devices and timing-sensitive control schemes.
Gerelateerde Links
- ABB 1SBL41 Contactor 230 V Coil 75 A 220V 3 NO, 690V
- ABB 1SBL41 Contactor 240 V Coil 230 V 690V
- ABB 1SBL41 Contactor 230 V ac Coil 125 A 230V 4 NO/1 NC, 690V
- ABB 1SBL41 Contactor 260 V Coil 1.3 kA 240V 3 NO, 1kV
- ABB 1SBL2 Contactor 230 V Coil 30 A 220V 4 NO, 690V
- ABB 1SBL18 Contactor 230 V Coil 16 A 220V 4 NO, 690V
- ABB 1SBL41 Contactor 120 V Coil 4 A 110V 1kV
- Eaton DILM Contactor 230 V ac/dc Coil 185 A 1 NO, 1kV