ABB GJL131 Contactor, 48V ac Coil, 3-Pole, 20 A, 5.5 kW 48V ac, 4 NO, 690V
- RS-stocknr.:
- 253-4796
- Fabrikantnummer:
- GJL1311001R0103
- Fabrikant:
- ABB
Afbeelding representeert productcategorie
Subtotaal (1 verpakking van 10 eenheden)*
€ 526,26
(excl. BTW)
€ 636,77
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk | Per verpakking* |
|---|---|---|
| 10 + | € 52,626 | € 526,26 |
*prijsindicatie
- RS-stocknr.:
- 253-4796
- Fabrikantnummer:
- GJL1311001R0103
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 48V ac | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Function | Mini Contactor | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Auxiliary Contact Configuration | 1 NO/0 NC | |
| Terminal Type | Screw | |
| Operational Current Ie | 20A | |
| Minimum Operating Temperature | -25°C | |
| Control Circuit Voltage Uc | 48V ac | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Width | 53mm | |
| Length | 46.7mm | |
| Standards/Approvals | UL 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | |
| Depth | 46.7mm | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Contactor | ||
Coil Voltage 48V ac | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Function Mini Contactor | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Auxiliary Contact Configuration 1 NO/0 NC | ||
Terminal Type Screw | ||
Operational Current Ie 20A | ||
Minimum Operating Temperature -25°C | ||
Control Circuit Voltage Uc 48V ac | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Width 53mm | ||
Length 46.7mm | ||
Standards/Approvals UL 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | ||
Depth 46.7mm | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- DE
ABB GJL131 Series Contactor, 20A Operational Current, 48V AC Control Circuit Voltage - GJL1311001R0103
This contactor provides Compact switching for commercial electrical systems, designed to control three-phase circuits and motor loads. It is intended for installation on a DIN rail or wall and operates with a 48V AC control supply, offering a Compact footprint suited to confined control panels while meeting recognised industrial standards.
Features and Benefits:
• Three-pole switching delivering 20 A operational current for motor control
• Rated for 690V enabling high-voltage industrial power handling
• 5.5 kW power capacity for moderate motor loads
• Single auxiliary contact configuration offering one NO contact for control logic
• Screw terminals providing secure conductor connections for field wiring
• Narrow 52.5mm width saving panel space in distribution assemblies
• Rated for 690V enabling high-voltage industrial power handling
• 5.5 kW power capacity for moderate motor loads
• Single auxiliary contact configuration offering one NO contact for control logic
• Screw terminals providing secure conductor connections for field wiring
• Narrow 52.5mm width saving panel space in distribution assemblies
Applications
• Suitable for controlling small to medium three-phase motors in factories
• Ideal for automation control panels requiring DIN rail mounting
• Used for switching industrial power circuits up to 690 V
• Can be used for commercial HVAC motor starters and pump control
• Ideal for automation control panels requiring DIN rail mounting
• Used for switching industrial power circuits up to 690 V
• Can be used for commercial HVAC motor starters and pump control
What environmental temperatures can it tolerate during operation?
It is specified to operate between -25 °C and 55 °C, allowing use in typical plant-room and indoor panel environments.
How many poles and auxiliary contacts are available for control schemes?
The device provides three main poles and one auxiliary normally open contact for signalling or interlock functions.
What mounting and Terminal options support installation flexibility?
It supports both DIN rail and wall mounting and uses screw-type terminals for direct conductor connection.
Which standards govern its design and safety characteristics?
It conforms to IEC/EN and UL standards relevant to low-voltage switching devices and auxiliary control circuits.
Gerelateerde Links
- ABB GJL131 Contactor 3-Pole 5.5 kW 48V ac 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 48V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 48V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 48V ac 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 48V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 48V 690V dc
- ABB GJL131 Contactor 3-Pole 5.5 kW 48V 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 690V