ABB GJL131 Contactor, 24V Coil, 3-Pole, 12 A, 5.5 kW 24V, 3 NO/1 NC, 220V dc
- RS-stocknr.:
- 253-4848
- Fabrikantnummer:
- GJL1313919R0011
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 84,75
(excl. BTW)
€ 102,55
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending vanaf 31 december 9999
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 84,75 |
*prijsindicatie
- RS-stocknr.:
- 253-4848
- Fabrikantnummer:
- GJL1313919R0011
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Coil Voltage | 24V | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 220V dc | |
| Contact Current | 12A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Mount Type | DIN Rail | |
| Function | Reversing Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Main Circuit Terminal | |
| Operational Current Ie | 12A | |
| Control Circuit Voltage Uc | 24V | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Width | 58mm | |
| Length | 47.7mm | |
| Depth | 47.7mm | |
| Standards/Approvals | UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, IEC/EN 60947-5-1 | |
| Pole and Throw Configuration | 3P | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Coil Voltage 24V | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 220V dc | ||
Contact Current 12A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Mount Type DIN Rail | ||
Function Reversing Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Main Circuit Terminal | ||
Operational Current Ie 12A | ||
Control Circuit Voltage Uc 24V | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Width 58mm | ||
Length 47.7mm | ||
Depth 47.7mm | ||
Standards/Approvals UL 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, IEC/EN 60947-5-1 | ||
Pole and Throw Configuration 3P | ||
- Land van herkomst:
- DE
ABB GJL131 Series Contactor, 24V Coil Voltage, 12A Contact Current - GJL1313919R0011
This contactor is a three-pole switching device designed to control AC circuits in commercial, industrial and residential installations. It operates with a 24V control Coil to enable reversing contactor arrangements and is suitable where compact, rail-mounted switching is required.
Features and Benefits:
• 3P switching for three-phase control and straightforward motor reversing
• 12 A operational current allowing safe switching of moderate loads
• 690V rated contact voltage for high-voltage AC applications
• 5.5 kW power rating for motor and machinery control tasks
• DIN-rail mount for Rapid installation and panel integration
• Solder-pin terminals enabling secure PCB or connector attachment
• 12 A operational current allowing safe switching of moderate loads
• 690V rated contact voltage for high-voltage AC applications
• 5.5 kW power rating for motor and machinery control tasks
• DIN-rail mount for Rapid installation and panel integration
• Solder-pin terminals enabling secure PCB or connector attachment
Applications
• Suitable for reversing small motors in factory automation panels
• Ideal for controlling HVAC compressors in commercial buildings
• Used with lighting distribution in residential multi-way circuits
• Can be used for machinery control in light industrial equipment
• Ideal for controlling HVAC compressors in commercial buildings
• Used with lighting distribution in residential multi-way circuits
• Can be used for machinery control in light industrial equipment
What auxiliary contact functionality is available for signalling or interlocking?
It provides a single auxiliary contact configured normally closed to support interlock or status feedback circuits.
What environmental temperatures can it tolerate during operation?
The device is specified to function between -20 °C and 55 °C for typical indoor electrical enclosures.
How many poles carry the main switching function and what is the pole arrangement?
Three poles perform the main switching operation in a 3P configuration suited to three-phase systems.
What mounting method is specified for panel fitting and service access?
It is designed for DIN-rail mounting to simplify replacement and wiring in control panels.
Which standards govern its electrical and safety characteristics?
It conforms to IEC/EN and UL 60947 series standards covering controlgear and contactor performance.
Gerelateerde Links
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 600V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 690V
- ABB GJL131 Contactor 240 V Coil 20 A 3 NO/1 NC 690V ac
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 250 V dc, 690V ac
- ABB GJL131 Contactor 240 V Coil 20 A 240 V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V 690V