Better World

Schneider Electric ICT Contactor, 230 V ac Coil, 2-Pole, 40 A, 1.6 W 240 V, 2 NO, 250V

Afbeelding representeert productcategorie

Subtotaal (1 eenheid)*

€ 140,99

(excl. BTW)

€ 170,60

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • Plus verzending 1 stuk(s) vanaf 02 februari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 140,99

*prijsindicatie

Better World

Ons Better World assortiment bevat producten die het u gemakkelijk maken om een groenere productkeuze te maken waarop u kunt vertrouwen. Klik hier voor meer informatie.

RS-stocknr.:
791-2969
Fabrikantnummer:
A9C21842
Fabrikant:
Schneider Electric
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Schneider Electric

Product Type

Contactor

Coil Voltage

230 V ac

Number of Poles

2

Contact Voltage

250V

Contact Current

40A

Series

ICT

Power Rating

1.6W

Function

Motor Control

Mount Type

DIN Rail

Normal State Configuration

2 NO

Auxiliary Contact Configuration

2 NO

Number of Auxiliary Contacts

2

Terminal Type

Screw

Contactor Application

Motor Control

Control Circuit Voltage Uc

240 V

Minimum Operating Temperature

-5°C

Operational Current Ie

40A

Maximum Operating Temperature

60°C

Length

36mm

Standards/Approvals

RoHS, IEC/EN 61095

Width

85 mm

Depth

73mm

Better World Product

Yes

Pole and Throw Configuration

2P

Schneider Electric Acti 9 iCT Contactors


ACTi 9 iCT Contactors from Schneider Electric provides power switching in single phase 3 phase loads. TeSys GC is a range of contactors that are safe, simple to use, and easy to install. The devices are compact in size and suitable for use in a wide variety of applications.

Features and Benefits


• Built-in auxiliary contacts for added switching capability

• Screw connections: IP20 finger-safe terminals with both North American and International terminal markings

• Can be panel mounted with screws or DIN Rail mounted

• Impulse relay function

• Day-night function

• Class-2 insulation: continuous safety for operators and unqualified personnel

What is the difference between AC-7a and AC-7b when choosing a iCT contactor?


These utilization catagories determine what load the contactors are switching:

AC-7a are for slightly inductive loads for household appliances for example mixers and blenders

AC-7b are for motor-loads for house hold appliances such as fans and central vacuums

Do spacers have to be fitted between the iCT range of Contactors?


If several contactors are fitted onto an DIN Rail then spacers should be used after every second contactor. The reason for this is that with multiple contactors side by side there can be a very high build of heat causing the devices to reach above their operating temperature. The coils themselves are 100% rated so can be on for 24 hours a day and the heat needs to be dissipated, therefore a spacer is required

Gerelateerde Links