Alpha Wire, 1.23mm², Unscreened Polyvinyl Chloride Sheath

Subtotaal (1 rol van 30 meter)*

€ 283,60

(excl. BTW)

€ 343,16

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending 10 stuk(s) vanaf 19 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len)
Per rol
Per meter*
1 +€ 283,60€ 9,453

*prijsindicatie

RS-stocknr.:
873-1276
Fabrikantnummer:
25072 BK005
Fabrikant:
Alpha Wire
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Alpha Wire

Jacket Material

Polyvinyl Chloride

Armoured

Yes

Screened/Unscreened

Unscreened

Core Strands

19

Belden Xtra-Guard 2 Performance Cable Series Control Cable, 30m Cable Length, 2 Cores - 25072 BK005


This control cable is designed for industrial signal and control circuits in automation and electrical installations. It comprises two conductors with tinned copper strands and a black PVC outer sheath, providing a flexible connection for equipment operating within a wide temperature range. The cable is unscreened and rated for 300V use, making it suitable for general-purpose control wiring where a flame-retardant construction is required.

Features & Benefits


• 19-strand tinned copper offers enhanced flexibility for routing
• Flame-retardant jacket reduces fire propagation risk in installations
• Rated 300V to support common control-voltage systems
• Operating range -30°C to 90°C enables varied environmental use
• Unscreened design simplifies connections for non‑noisy circuits
• PVC outer sheath provides chemical and abrasion resistance

Applications


• Suitable for factory automation control panels and wiring
• Ideal for motor starter and relay interconnections
• Used for sensor and actuator cabling in machinery
• Can be used for general-purpose control runs in plant wiring
• Used with Terminal blocks and cable assemblies for equipment racks

What conductor construction ensures flexibility for tight bends?


Each conductor contains 19 tinned copper strands, which reduces stiffness and aids installation around bends.

How should bend radius be managed during installation?


Maintain a minimum bend radius of 10x the cable diameter to prevent conductor stress.

What labelling or marking is present on the cable?


The jacket is printed with manufacturer identification, part details and sequence footage marking for traceability.

What mechanical loads can the cable tolerate during pull‑in?


Maximum permissible pull tension is 41 lb during installation to avoid damage.

Which regulatory designations apply to its construction?


The cable conforms to recognised AWM styles and meets fire test and low‑voltage directives applicable to control wiring.