Fluke i2000 Current Probe, 2 kA AC Max, UKAS
- RS-stocknr.:
- 654-1260
- Fabrikantnummer:
- I2000 FLEX
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 618,00
(excl. BTW)
€ 747,78
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- 4 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 618,00 |
*prijsindicatie
- RS-stocknr.:
- 654-1260
- Fabrikantnummer:
- I2000 FLEX
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Current Probe | |
| Maximum AC Current | 2kA | |
| Accuracy | ±1 % | |
| Maximum Conductor Size | 178mm | |
| Cable Length | 2m | |
| Connector Type | Plug | |
| Battery Type | 2 x AA | |
| Minimum Operating Temperature | 0°C | |
| Battery Life | 200h | |
| Maximum Operating Temperature | 70°C | |
| Standards/Approvals | EN 61326 | |
| Model Number | i2000 | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Current Probe | ||
Maximum AC Current 2kA | ||
Accuracy ±1 % | ||
Maximum Conductor Size 178mm | ||
Cable Length 2m | ||
Connector Type Plug | ||
Battery Type 2 x AA | ||
Minimum Operating Temperature 0°C | ||
Battery Life 200h | ||
Maximum Operating Temperature 70°C | ||
Standards/Approvals EN 61326 | ||
Model Number i2000 | ||
Safety Category Level CAT III | ||
Safety Category Voltage 600V | ||
Calibrated UKAS | ||
N.v.t.
- Land van herkomst:
- CN
Fluke Current Probe, 2kA Maximum AC Current, 178mm Maximum Conductor Size - I2000 FLEX
This current probe is a flexible Rogowski-type clamp designed to measure high alternating currents when used alongside multimeters, recorders or data loggers. It gives technicians a practical solution for accessing confined or awkward wiring runs and delivers readings suitable for industrial and laboratory environments within standard safety limits.
Features & Benefits
• Measures up to 2000A ac rms for high-current diagnostics
• Switchable 20A, 200A and 2000A ranges for versatile measurement
• ±1% accuracy across 45Hz–65Hz for dependable readings
• 2m cable with BNC output and plug connector for easy linking
• 200h battery life from two AA cells for extended field use
• CAT III 600V safety rating for use on building installations
• Switchable 20A, 200A and 2000A ranges for versatile measurement
• ±1% accuracy across 45Hz–65Hz for dependable readings
• 2m cable with BNC output and plug connector for easy linking
• 200h battery life from two AA cells for extended field use
• CAT III 600V safety rating for use on building installations
**Applications**
• Suitable for commissioning large motors and drives
• Ideal for load studies and temporary power monitoring
• Used with handheld multimeters in service rounds
• Can be used for fault‑finding in switchgear and panels
• Used for waveform logging with data acquisition systems
• Ideal for load studies and temporary power monitoring
• Used with handheld multimeters in service rounds
• Can be used for fault‑finding in switchgear and panels
• Used for waveform logging with data acquisition systems
What temperature range can the sensor head tolerate during use?
The head is rated to operate between 0°C and +70°C, permitting on‑site measurements in typical industrial environments.
How does the probe connect to measurement instruments?
The output is via a BNC connection with an included BNC‑to‑banana adaptor, enabling attachment to multimeters and loggers.
How does positional placement of the conductor affect measurements?
Position sensitivity increases with conductor proximity
readings are typically within a few per cent when the conductor is more than 25mm from the coupling and may rise when closer.
What frequency span does it support for accurate measurement?
The device remains responsive from 10Hz up to several kilohertz with specified phase and amplitude behaviour across that band.
What approvals relate to electromagnetic compatibility?
The unit complies with EN 61326 for EMC performance as specified for measurement equipment.
Gerelateerde Links
- Fluke i2000 Current Probe, 2 kA AC Max
- Fluke i2000 Current Probe RSCAL
- Fluke i6000S FLEX Current Probe UKAS
- Fluke i6000S FLEX Current Probe, 6 kA AC Max
- Fluke i3000S Current Probe Voltage Output, UKAS
- Fluke i6000S FLEX Current Probe RSCAL
- Fluke i6000S FLEX Current Probe 6 kA AC Max, Current Output
- Fluke i3000S Current Probe Current Output