Siemens SENTRON Series Current Transformer 150 A 150:5 2.5 VA 720V

Subtotaal (1 eenheid)*

€ 86,25

(excl. BTW)

€ 104,36

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 5 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 86,25

*prijsindicatie

RS-stocknr.:
175-6142
Fabrikantnummer:
4NC5121-2CC21
Fabrikant:
Siemens
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Siemens

Product Type

Current Transformer

Series

SENTRON

Power Rating

2.5VA

Secondary Current

5A

Terminal Type

Screw

Primary Current

150A

Minimum Operating Temperature

-30°C

Maximum Operating Temperature

55°C

Depth

55mm

Weight

304g

Standards/Approvals

DIN EN 61346-2

Width

60mm

Turns Ratio

150:5

Supply Voltage

720V

Land van herkomst:
IN

Siemens SENTRON Series Current Transformer, 150A primary current, 5A secondary Current - 4NC5121-2CC21


This current transformer converts high primary currents to a standard secondary for measurement and protection tasks in low-voltage networks. It is designed for indoor electrical installations, with an insulation rating suitable for systems up to 0.72 kV and operation across standard power frequencies. The device incorporates a bushing-style through-conductor arrangement and provides touch-protected connections for safe integration with existing switchgear and metering equipment.

Features and Benefits:


• 150:5 turns ratio delivers predictable scaling for instruments
• 2.5 VA power rating CT limits burden on measurement circuits
• Class 1 accuracy ensures measured values meet metering tolerances
• Screw-terminal current transformer enables secure conductor termination
• Rated for -30 to 55°C operation for varied plant environments

Applications


• Suitable for panel-mounted energy monitoring installations
• Used with metering relays for overcurrent detection tasks
• Ideal for integration into distribution switchboards
• Can be used for industrial load current measurement points
• Used for protection coordination studies in substations

What short-time thermal capability does it use?


The rated short-time thermal current is specified as a multiple of the primary rated current using the formula Ith = x·Ipr per IEC 61869-2.

How is dynamic withstand defined for fault conditions?


Dynamic current is given as Idyn = 2.5·Ith or 150·Ipr according to IEC 61869 for the design.

What mechanical fixing and conductor sizes are supported?


It fastens by screw fixing and accepts a push-through conductor or busbar with up to 19 mm outer diameter.

What protection and indoor suitability does it provide?


It has IP20 ingress protection, touch-protection features, and is intended for interior use only.