LEM ATO Series Split Core Current Transformer, 100A Input, 100:1, 16mm Bore
- RS-stocknr.:
- 177-4929
- Fabrikantnummer:
- ATO-100-B333-D16
- Fabrikant:
- LEM
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 177-4929
- Fabrikantnummer:
- ATO-100-B333-D16
- Fabrikant:
- LEM
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | LEM | |
| Current Ratio | 100:1 | |
| Series | ATO | |
| Bore Size | 16mm | |
| Transformer Type | Split Core | |
| Input Current | 100A | |
| Overall Height | 56.1mm | |
| Overall Width | 40.8mm | |
| Overall Depth | 33.2mm | |
| Minimum Temperature | -10°C | |
| Maximum Temperature | +55°C | |
| Mounting Type | DIN Rail | |
| Alles selecteren | ||
|---|---|---|
Merk LEM | ||
Current Ratio 100:1 | ||
Series ATO | ||
Bore Size 16mm | ||
Transformer Type Split Core | ||
Input Current 100A | ||
Overall Height 56.1mm | ||
Overall Width 40.8mm | ||
Overall Depth 33.2mm | ||
Minimum Temperature -10°C | ||
Maximum Temperature +55°C | ||
Mounting Type DIN Rail | ||
- Land van herkomst:
- CN
ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement).ATO series is an ideal current transformer for new Smart-Grid applications.
Split-core current transformer
Accuracy class 1
Voltage output 333 mV at IPr
⌀ 16 mm sensing aperture
1 m output cable
Ambient temperature −10 °C … +55 °C
Very low cost solution
Slot for attaching the C.T. on the primary with plastic tie
DIN rail adapter (optional).
No interruption of electricity during installation on insulated conductors
Quick, non-intrusive and easy setup
Provide a calibrate output.
Accuracy class 1
Voltage output 333 mV at IPr
⌀ 16 mm sensing aperture
1 m output cable
Ambient temperature −10 °C … +55 °C
Very low cost solution
Slot for attaching the C.T. on the primary with plastic tie
DIN rail adapter (optional).
No interruption of electricity during installation on insulated conductors
Quick, non-intrusive and easy setup
Provide a calibrate output.
Gerelateerde Links
- LEM ATO Series Split Core Current Transformer 50:1, 10mm Bore
- LEM AT Series Current Transformer 100:1, 16mm Bore
- LEM TT Series Current Transformer 100:1 16mm Bore
- LEM AT Series Current Transformer 100:1 16mm Bore, 20 → 30 V dc
- ENTES ENS.CCT Series Split Core Current Transformer 333 mV Output, 16mm Bore
- Socomec 192T Series Split Core Current Transformer 100:5
- LEM HOYS Series Base Mounted Current Transformer 100:1, +5 V
- LEM AP Series Current Transformer 100:1 24 V dc