TRACOPOWER TVN 3 DC/DC Converter, 15V dc/ 100 mA, 18V dc Input, 9V Input 3 W, Through Hole, 90 °C Max Temp -40 °C Min

Afbeelding representeert productcategorie

Bulkkorting beschikbaar

Subtotaal (1 tube van 10 eenheden)*

€ 376,33

(excl. BTW)

€ 455,36

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 07 oktober 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.

Tube(s)
Per tube
Per stuk*
1 - 4€ 376,33€ 37,633
5 - 9€ 365,03€ 36,503
10 - 24€ 353,75€ 35,375
25 - 49€ 338,69€ 33,869
50 +€ 323,64€ 32,364

*prijsindicatie

RS-stocknr.:
146-5929
Fabrikantnummer:
TVN 3-1223
Fabrikant:
TRACOPOWER
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

TRACOPOWER

Product Type

DC/DC Converter

Output Voltage 1

15V dc

Maximum Input Voltage

18V dc

Minimum Input Voltage

9V

Output Current 1

100mA

Output Current 2

100mA

Output Voltage 2

-15V dc

Mount Type

Through Hole

Input Ratio

2:1

MTBF

5600000h

Number of Outputs

2

Number of Pins

12

Isolation Voltage

1.6kV dc

Package Type

SIP

Maximum Output Power

3W

Width

9.6mm

Length

21.8mm

Standards/Approvals

No

Series

TVN 3

Depth

11.2mm

Efficiency

83%

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

90°C

Land van herkomst:
TW
The THM 15WI series is a range of medical 15 Watt DC/DC converters in 1.6” x 1.0” plastic package and with wide 2:1 input voltage range. They provide a reinforced isolation system for 5000 VACrms isolation and a very low leakage current of less than 2.5 μA. The units are approved to IEC/EN/ES 60601-1 3rd edition for 2 x MOPP (Means Of Patient Protection) and come along with an ISO 14971 risk management file. Design and production conform to the quality management system ISO 13485.

I/O isolation 5000 VACrms rated for 250 VACrms working voltage

Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP

Risk management process according to ISO 14971 including risk management file

Extended operating temperature range –40°C to 85°C.

EMC compliance to IEC 60601-1-2 4th edition and EN55032 class A