Fluke calibration, RTD Probe Handheld 1551A Digital Thermometer, 1 Input(s), +160 °C Max, ±0.05°C Accuracy, UKAS
- RS-stocknr.:
- 735-6489
- Fabrikantnummer:
- 1551A-12
- Fabrikant:
- Fluke calibration
Subtotaal (1 eenheid)*
€ 1.356,84
(excl. BTW)
€ 1.641,78
(incl. BTW)
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.356,84 |
*prijsindicatie
- RS-stocknr.:
- 735-6489
- Fabrikantnummer:
- 1551A-12
- Fabrikant:
- Fluke calibration
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke calibration | |
| Product Type | Digital Thermometer | |
| Maximum Temperature Measurement | +160°C | |
| Model Number | 1551A | |
| Probe Type | RTD | |
| Thermometer Type | Handheld | |
| Accuracy | ±0.05°C | |
| Number of Temperature Inputs | 1 | |
| Power Source | Battery | |
| Resolutions Supported | 0.001°C | |
| Battery Life | 300h | |
| Length | 114mm | |
| Weight | 196g | |
| Hazardous Area Certification | ATEX | |
| Standards/Approvals | CISPR II Edition 5.0-2009, EN61326:2006 Annex C | |
| Width | 57mm | |
| Height | 25mm | |
| Temperature Scale | F, Fahrenheit, °C | |
| Minimum/Maximum Recordings | Yes | |
| Application | Industrial | |
| Intrinsically Safe | Yes | |
| Battery Type | 3 x AAA Alkaline | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke calibration | ||
Product Type Digital Thermometer | ||
Maximum Temperature Measurement +160°C | ||
Model Number 1551A | ||
Probe Type RTD | ||
Thermometer Type Handheld | ||
Accuracy ±0.05°C | ||
Number of Temperature Inputs 1 | ||
Power Source Battery | ||
Resolutions Supported 0.001°C | ||
Battery Life 300h | ||
Length 114mm | ||
Weight 196g | ||
Hazardous Area Certification ATEX | ||
Standards/Approvals CISPR II Edition 5.0-2009, EN61326:2006 Annex C | ||
Width 57mm | ||
Height 25mm | ||
Temperature Scale F, Fahrenheit, °C | ||
Minimum/Maximum Recordings Yes | ||
Application Industrial | ||
Intrinsically Safe Yes | ||
Battery Type 3 x AAA Alkaline | ||
Calibrated UKAS | ||
Niet conform
- Land van herkomst:
- US
Fluke Digital Thermometer, ±0.05°C Accuracy, +160°C Maximum Temperature Measurement - 1551A-12
Features & Benefits
• Intrinsically safe certification allows use in explosive atmospheres
• Optional internal logging stores up to 10,000 time-stamped readings
• User-selectable resolution improves detail for fine measurements
• 300h typical battery life from three AAA cells extends field use
• Stability/trend indication confirms when a measurement is steady
**Applications**
• Ideal for temperature verification during custody transfer checks
• Used with industrial ovens and chillers for quality control
• Can be used for on-site validation of food-processing lines
• Used for routine maintenance of electrical and mechanical systems
What sensor type does it use and how does that affect drift?
How does the instrument handle data transfer and configuration?
What environmental conditions limit its readout performance?
What immersion depth and response times should I expect for reliable readings?
Note
Supplied with
Gerelateerde Links
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, RSCAL
- Fluke calibration 1 Input(s) ±0.05°C Accuracy, UKAS