Fluke 1625 Earth Tester Kit CAT II 300V RSCAL
- RS-stocknr.:
- 797-6853
- Fabrikantnummer:
- FLUKE-1625-2 KIT
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 5.634,00
(excl. BTW)
€ 6.817,14
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Beperkte voorraad
- Plus verzending 4 stuk(s) vanaf 20 april 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 5.634,00 |
*prijsindicatie
- RS-stocknr.:
- 797-6853
- Fabrikantnummer:
- FLUKE-1625-2 KIT
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Earth Tester Kit | |
| Accuracy | ±7 % + 2 Digits | |
| Display Type | LCD | |
| Measurement Type | Earth Resistance | |
| Battery Life | 6000h | |
| Battery Type | AA | |
| Power Source | Battery | |
| Weight | 1.1kg | |
| Height | 133mm | |
| Includes | Cable Reel, User Manual, Batteries, Carrying Case | |
| Length | 250mm | |
| Standards/Approvals | No | |
| Maximum Operating Temperature | 35°C | |
| Minimum Operating Temperature | 0°C | |
| Calibrated | RSCAL | |
| Model Number | 1625 | |
| Safety Category Voltage | 300V | |
| Safety Category Level | CAT II | |
| Width | 187mm | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Earth Tester Kit | ||
Accuracy ±7 % + 2 Digits | ||
Display Type LCD | ||
Measurement Type Earth Resistance | ||
Battery Life 6000h | ||
Battery Type AA | ||
Power Source Battery | ||
Weight 1.1kg | ||
Height 133mm | ||
Includes Cable Reel, User Manual, Batteries, Carrying Case | ||
Length 250mm | ||
Standards/Approvals No | ||
Maximum Operating Temperature 35°C | ||
Minimum Operating Temperature 0°C | ||
Calibrated RSCAL | ||
Model Number 1625 | ||
Safety Category Voltage 300V | ||
Safety Category Level CAT II | ||
Width 187mm | ||
Vrijgesteld
- Land van herkomst:
- RO
Fluke Earth Tester Kit, ±5 % rdg Accuracy, Battery Life 6000h - FLUKE-1625-2 KIT
This earth tester kit is a battery‑powered instrument for measuring earth resistance and soil resistivity in outdoor and indoor environments. It supports multiple test methods including fall‑of‑potential, selective clamp testing and stakeless clamp‑based loop measurements, and stores test records for later transfer via USB.
Features & Benefits
• ±5% accuracy Plus 5 digits for precise readings
• AFC and R* modes reduce interference and reflect 55Hz impedance
• Internal memory holds up to 1500 records for data logging
• Stakeless measurement with two clamps avoids stake placement
• IP56 protection permits use in wet and dusty conditions
• Battery operation delivers up to 6000 h life with AA cells
• AFC and R* modes reduce interference and reflect 55Hz impedance
• Internal memory holds up to 1500 records for data logging
• Stakeless measurement with two clamps avoids stake placement
• IP56 protection permits use in wet and dusty conditions
• Battery operation delivers up to 6000 h life with AA cells
Applications
• Suitable for field service fault‑to‑earth verification in power systems
• Ideal for industrial maintenance earth resistance surveys
• Used for soil earth resistance measurement in telecom sites
• Can be used for selective rod testing without disconnection
• Used with clamps for loop resistance checks inside substations
• Ideal for industrial maintenance earth resistance surveys
• Used for soil earth resistance measurement in telecom sites
• Can be used for selective rod testing without disconnection
• Used with clamps for loop resistance checks inside substations
How is data transferred from the instrument for reporting?
Stored records are exported through a USB port for PC download and analysis.
What safety and electrical limits should I observe during testing?
Measurement is inhibited if external voltages exceed 24V and the instrument withstands misuse up to 250 Vrms between sockets.
Which battery configuration is required and what is typical lifespan?
Six AA alkaline cells power the unit with typical measurement counts up to 6000 h depending on load conditions.
How does the instrument handle noisy environments or mains interference?
Noise rejection is specified up to 120 dB and automatic frequency selection identifies interference and selects a measurement frequency.
Are there restrictions on clamp use for stakeless testing?
Stakeless loop measurement requires the recommended current clamps and adherence to minimum spacing for valid results.
Supplied with
6 x AA LR6 batteries, 6 x test leads, 4 x earth ground stakes, 3 x cable reels with wire (2 x 25 m, 1 x 50 m), 2 x clamps (one inducing, one sensing), users manual, carrying case.
Gerelateerde Links
- Fluke 1625 CAT II 300V
- Fluke 1625-2 Earth Tester, 300 kΩ CAT II 300V RSCAL
- Fluke 1625-2 Earth Tester, 300 kΩ CAT II 300V
- Fluke 1623-2 CAT II 300V RSCAL
- Fluke 1623 Earth Tester, 20 kΩ CAT II 300V RSCAL
- Fluke 1623-2 CAT II 300V
- Fluke 1623 Earth Tester, 20 kΩ CAT II 300V
- Fluke 1623 Earth Tester, 20 kΩ CAT II 300V UKAS