Phoenix Contact RIF-1-RSC-LDP-24DC/2X21MS Series Interface Relay, DIN Rail, 24V dc Coil, DPDT, 18mA

Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.

Alternatief

Dit product is momenteel niet beschikbaar. Hierbij onze aanbeveling voor een alternatief product.

Per stuk

€ 10,68

(excl. BTW)

€ 12,92

(incl. BTW)

RS-stocknr.:
175-0526
Fabrikantnummer:
2905660
Fabrikant:
Phoenix Contact
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Phoenix Contact

Product Type

Interface Relay

Coil Voltage

24V dc

Contact Configuration

DPDT

Mount Type

DIN Rail

Series

RIF-1-RSC-LDP-24DC/2X21MS

Terminal Type

Screw

Switching Current

10mA

Switching DC Voltage

250V dc

Coil Current

18mA

Minimum Operating Temperature

-40°C

Switching AC Voltage

250V ac

Contact Material

Silver Alloy

Maximum Operating Temperature

60°C

Height

89mm

Width

75mm

Length

16mm

Standards/Approvals

IEC 60947-5-1

Land van herkomst:
CN
This time relay RIF-1-RSC-LDP-24DC/2X21MS 2905660 from Phoenix Contact is the cost-effective alternative to a PLC; with easy configuration and fast wiring.

Features and Benefits


  • Pre-assembled relay module

  • Screw connection

  • Consists of: relay base, relay retaining bracket, and power contact relay with test button, integrated status LED, and freewheeling diode

  • Contact type: 2 changeover contacts

  • Time-saving potential distribution, thanks to plug-in bridges

  • Protection against operating errors due to manual operation that is lockable via screwdriver

  • Quick and error-free connection to the controller via system cabling

  • Safety


    When working on the products and the system, you must always keep the operating instructions and other items of product documentation to hand and follow them strictly.

    Demands on the power supply


    Only use power supply units that ensure safe isolation between the primary and secondary circuits according to EN 50178.

    Applications


    You can use the same electromechanical relay module design for both AC and DC switching module.

  • Electrical isolation

  • Voltage adjustment of frequently varying voltage levels

  • Power amplification

  • Signal multiplication in the case of relay modules with multiple contacts (e.g., for signal confirmations)

  • Approvals


    IECEx, ATEX and Class 1 Zone 2

    Phoenix Contact RIF-1-RSC