Schneider Electric TeSys Deca TeSyS GV Electronic Circuit Breaker 2.5A 690V, DIN Rail Type AC
- RS-stocknr.:
- 276-1598
- Fabrikantnummer:
- GV2ME073
- Fabrikant:
- Schneider Electric
Subtotaal (1 eenheid)*
€ 85,54
(excl. BTW)
€ 103,50
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 3 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 85,54 |
*prijsindicatie
Ons Better World assortiment bevat producten die het u gemakkelijk maken om een groenere productkeuze te maken waarop u kunt vertrouwen.
Lees meer over de RS Better World producten
- RS-stocknr.:
- 276-1598
- Fabrikantnummer:
- GV2ME073
- Fabrikant:
- Schneider Electric
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Schneider Electric | |
| Range | TeSys Deca | |
| Product Type | Electronic Circuit Breaker | |
| Series | TeSyS GV | |
| Current Rating | 2.5A | |
| Voltage | 690V | |
| Breaking Capacity | 100kA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type AC | |
| Length | 101mm | |
| Terminal Type | Spring | |
| Width | 45mm | |
| Depth | 78.5mm | |
| Standards/Approvals | EN/IEC 60947-2 | |
| Better World Claim | Designed for Disassembly | |
| Better World Product | Yes | |
| Alles selecteren | ||
|---|---|---|
Merk Schneider Electric | ||
Range TeSys Deca | ||
Product Type Electronic Circuit Breaker | ||
Series TeSyS GV | ||
Current Rating 2.5A | ||
Voltage 690V | ||
Breaking Capacity 100kA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type AC | ||
Length 101mm | ||
Terminal Type Spring | ||
Width 45mm | ||
Depth 78.5mm | ||
Standards/Approvals EN/IEC 60947-2 | ||
Better World Claim Designed for Disassembly | ||
Better World Product Yes | ||
Vrijgesteld
- Land van herkomst:
- FR
Schneider Electric GV2ME Series Electronic Circuit Breaker, 2.5A Current, 100kA Breaking Capacity - GV2ME073
Features & Benefits
• 100kA Icu breaking capacity at common voltages for high fault clearance
• Type AC magnetic tripping characteristic for AC load discrimination
• Spring terminals enabling quick, vibration‑resistant wiring connections
• 690V rated insulation and operational voltage for high‑voltage compatibility
• Continuous rated duty with long electrical durability for sustained operation
Applications
• Ideal for use with contactors in motor‑starter assemblies
• Used for automation skid control and distributed motor protection
• Suitable for retrofit on 35mm DIN rails in plant switchgear
• Used for requiring phase‑failure sensitivity in drives
How is the device mounted in a control enclosure?
What operational environmental limits apply during use?
How does it behave under short‑circuit conditions at higher voltages?
What endurance can users expect from switching cycles?
Are there features for hazardous or marine environments?
Gerelateerde Links
- Schneider Electric TeSys Deca TeSyS GV Motor Protection Circuit Breaker - 3-Pole DIN Rail
- Schneider Electric TeSys Deca TeSyS GV Motor Protection Circuit Breaker - 3-Pole 40A Current Rating, 100 kA
- Schneider Electric TeSys Deca TeSyS GV Motor Protection Circuit Breaker - 3-Pole 5A Current Rating, 100 kA
- Schneider Electric TeSys Deca TeSyS GV Motor Protection Circuit Breaker - 3-Pole 32A Current Rating, 100 kA
- Schneider Electric 2.5A TeSyS GV Motor Protection Circuit Breaker 60 °C, -20 °C
- Schneider Electric 2.5A 690V -20 °C
- Schneider Electric TeSys Thermal Circuit Breaker - TeSyS GV 3 Pole 690V Voltage Rating DIN Rail Mount, 32A Current
- Schneider Electric TeSyS GV Connection Link for use with GV2 D