SICK ES21 Series Rotary release Illuminated Emergency Stop Push Button, Surface Mount, 1 NO/2 NC, IP54

Subtotaal (1 eenheid)*

€ 89,89

(excl. BTW)

€ 108,77

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 1 stuk(s) klaar voor verzending
  • Plus verzending 3 stuk(s) vanaf 20 oktober 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 89,89

*prijsindicatie

RS-stocknr.:
285-1304
Fabrikantnummer:
ES21-SA13H1 / 6034584
Fabrikant:
SICK
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

SICK

Mount Type

Surface Mount

Product Type

Emergency Stop Push Button

Contact Configuration

1 NO/2 NC

Push Button Actuation

Rotary release

Housing Material

Plastic

Illuminated

Yes

Series

ES21

IP Rating

IP54

Colour

Red

Contact DC Voltage

24V dc

Contact Current

3A

Contact AC Voltage

250V ac

Depth

31.4mm

Switch Configuration

Slow Action

Standards/Approvals

UL components (ES21-XS001,ES21-XC050,ES21-CS0010,ES21-CS0100,ES21-CS1000,ES21-AT1120). See UL certificate number: E198242

Length

31.4mm

Hazardous Area Certification

No

Width

41.5mm

Safety Contacts

2 NC, 1 NO

Push Button Material

Plastic

Land van herkomst:
DE

Overview


ES21 emergency stop pushbuttons are a must for automated machines and systems. They provide a means for a person to stop a machine or system in the event of an emergency.

Depending on the variant, the emergency stop pushbuttons are either integrated into a machine operator panel or mounted directly on the machine.

At a glance


Optionally available as a built-in version or as a surface-mounted version with housing

Built-in version with self-monitoring emergency stop contacts

Status display with colored mark or LED ring illumination

Variants with protective collar

Variants with M12 male connector

Your Benefit


A wide range of variants for custom-fit integration into your machine

High level of safety thanks to self-monitoring: It switches off the machine in the event of faulty installation or mechanical damage

Quick and User friendly reading of the device status

Reduction of unplanned machine stops, for instance in busy work areas

Can be installed quickly and cost effectively, at the same time reducing sources of error during wiring

Simple, safe series connection with Flexi Loop

Applications


Fields of applications

Safe stop function for machinery and systems

Gerelateerde Links