Belden 74005PU, 500 m Cat7 Cable, Black Polyurethane Sheath
- RS-stocknr.:
- 631-620
- Fabrikantnummer:
- 74005PU.02500
- Fabrikant:
- Belden
Subtotaal (1 rol van 500 meter)*
€ 1.692,61
(excl. BTW)
€ 2.048,06
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Tijdelijk niet op voorraad
- Verzending 1 stuk(s) vanaf 04 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 1.692,61 | € 3,385 |
*prijsindicatie
- RS-stocknr.:
- 631-620
- Fabrikantnummer:
- 74005PU.02500
- Fabrikant:
- Belden
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Belden | |
| Product Type | Cat7 Cable | |
| Series | 74005PU | |
| Cable Length | 500m | |
| Jacket Colour | Black | |
| Jacket Material | Polyurethane | |
| Conductor Type | Stranded | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 80°C | |
| Standards/Approvals | RoHS, EU CE, IEC 60332-1-2, UKCA | |
| Fire Behaviour | IEC 60332-1-2 | |
| Outside Diameter | 6.8mm | |
| Voltage | 450V | |
| Conductor Material | Bare Copper | |
| Number of Cores | 8 | |
| Alles selecteren | ||
|---|---|---|
Merk Belden | ||
Product Type Cat7 Cable | ||
Series 74005PU | ||
Cable Length 500m | ||
Jacket Colour Black | ||
Jacket Material Polyurethane | ||
Conductor Type Stranded | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 80°C | ||
Standards/Approvals RoHS, EU CE, IEC 60332-1-2, UKCA | ||
Fire Behaviour IEC 60332-1-2 | ||
Outside Diameter 6.8mm | ||
Voltage 450V | ||
Conductor Material Bare Copper | ||
Number of Cores 8 | ||
- Land van herkomst:
- HU
Belden 74005PU Series Thin Ethernet Cable, 500m Cable Length, Black Jacket - 74005PU.02500
This thin Ethernet cable provides a Compact solution for signal and network wiring in industrial settings, designed for reliable connectivity where space is limited and mechanical flexibility is required. It is intended for use in automated and machine-mounted installations operating across a broad temperature range and under standard voltage conditions.
Features and Benefits:
• 8-core stranded conductor for flexible routing and movement
• Bare copper conductors with 7 strands for enhanced conductivity
• Polyurethane black jacket resists abrasion in harsh environments
• Rated for 450V enabling safe low-voltage distribution
• Meets IEC 60332-1-2 for reduced flame propagation performance
• Operable from -40 to 80°C for wide ambient tolerance
• Bare copper conductors with 7 strands for enhanced conductivity
• Polyurethane black jacket resists abrasion in harsh environments
• Rated for 450V enabling safe low-voltage distribution
• Meets IEC 60332-1-2 for reduced flame propagation performance
• Operable from -40 to 80°C for wide ambient tolerance
Applications
• Suitable for cabling on production-line automation equipment
• Ideal for wiring control cabinets in electronics manufacturing
• Used for flexible interconnects on mobile machinery
• Can be used for network links in electrical panel installations
• Used with sensors and actuators in mechanical systems
• Ideal for wiring control cabinets in electronics manufacturing
• Used for flexible interconnects on mobile machinery
• Can be used for network links in electrical panel installations
• Used with sensors and actuators in mechanical systems
How does the conductor construction affect cable flexibility?
The conductors are stranded with seven strands per core, which increases pliability compared with solid conductors and reduces fatigue in repeated flexing applications.
What does the jacket material contribute to installation longevity?
The polyurethane sheath offers enhanced resistance to abrasion, oils and mechanical wear, extending service life where cables are routed through confined or moving paths.
Which approvals indicate suitability for regulatory environments?
The cable carries RoHS, EU CE and UKCA marks and conforms to IEC 60332-1-2, aligning it with common regulatory requirements for industrial installations.
How does the cables diameter influence routing options?
With an outside diameter of 6.8mm, the thin profile eases installation through conduits and tight cable channels while maintaining necessary core count.
What electrical parameters determine safe operating conditions?
The cable is specified for a maximum operating temperature of 80°C and is rated at 450V, defining the thermal and voltage limits for correct deployment.
Gerelateerde Links
- Belden 74005PU Shielded, Black Screened Polyurethane Sheath
- Belden 74005PU Tin Plated Copper Alloy Braid, Black Screened Polyethylene Sheath
- Belden 74004PU Black Polyurethane Sheath
- Belden 74004PU Shielded, Black Screened Polyurethane Sheath
- Belden Unterminated Black Polyvinyl Chloride Sheath
- Belden 74005NH Black Low Smoke Zero Halogen Sheath
- Belden 74004NH Black Low Smoke Zero Halogen Sheath
- Belden 74002NH Black Low Smoke Zero Halogen Sheath
