Festo MS Filter Regulator, 40 μm, 1/2 in G, Automatic, 10 bar, 8098312

Subtotaal (1 eenheid)*

€ 105,08

(excl. BTW)

€ 127,15

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 8 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 105,08

*prijsindicatie

RS-stocknr.:
253-9238
Artikelnummer Distrelec:
302-82-839
Fabrikantnummer:
MS6-LFR-1/2-D6-E-P-VC-AG-BAR-B
Fabrikant:
Festo
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Festo

Product Type

Filter Regulator

Port Size

1/2 in G

Maximum Operating Pressure

10 bar

Maximum Flow Rate

5300L/min

Series

MS

Connection Thread Standard

G

Drain Type

Automatic

Filtration Size

40μm

Pressure Gauge Port Size

1/2 in

Maximum Operating Temperature

50°C

Standards/Approvals

RoHS

Bowl Material

Polycarbonate

Pressure Gauge Port Thread Standard

G

Pressure Setting Range

0.3 to 7 bar

Model Number

8098312

Land van herkomst:
HU

Festo Filter Regulator, 27.3ml Maximum Condensate Volume, 2 to 10 Bar Operating Pressure - MS6-LFR-1/2-D6-E-P-VC-AG-BAR-B


Support your pneumatic system's pressure points with this filter regulator from Festo. The two-in-one solution controls outputs to maintain consistent airflow while removing contaminants for a more productive system. A fully-automatic condensate drain with a directly actuated control valve limits lag, so you're assured of efficient airflow and minimal downtime. An integrated gauge takes the guesswork out of monitoring and troubleshooting. The wide operating pressure range of 2 to 10 bar makes this a stress-free option for use in low-pressure and high-pressure applications. And, because durability is key, you can trust its tough PA-reinforced body to stand up to impacts.

Features & Benefits


• Standard G1/2 connection port for easy compatibility

• PE filter resists corrosive and abrasive damage

• Wide operating temperature range between +5°C and +50°C for use in harsh conditions

Applications


• Industrial air compressors

• Transport industry

• Medical barostat systems

• Dental equipment

Why is it important to keep the air in pneumatic systems clean?


Dust and other solid or liquid contaminants cause friction, affecting the overall system's performance. These also cause wear and tear, which limits the lifespan of equipment.

How do I set this filter regulator?


This regulator has a rotary knob to make adjustments. It includes a lock to prevent accidental resetting.

Gerelateerde Links