HARTING Han D Female Crimp Contact, 10A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty
- RS-stocknr.:
- 190-3355
- Fabrikantnummer:
- 09150006201
- Fabrikant:
- HARTING
Afbeelding representeert productcategorie
Bulkkorting beschikbaar
Bekijk bulkkortingSubtotaal (1 verpakking van 100 eenheden)*
€ 106,70
(excl. BTW)
€ 129,10
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 600 stuk(s) vanaf 10 augustus 2026
- Plus verzending 4.300 stuk(s) vanaf 10 augustus 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk | Per verpakking* |
|---|---|---|
| 100 - 100 | € 1,067 | € 106,70 |
| 200 - 300 | € 1,024 | € 102,40 |
| 400 - 900 | € 0,984 | € 98,40 |
| 1000 - 1400 | € 0,914 | € 91,40 |
| 1500 + | € 0,849 | € 84,90 |
*prijsindicatie
- RS-stocknr.:
- 190-3355
- Fabrikantnummer:
- 09150006201
- Fabrikant:
- HARTING
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | HARTING | |
| Product Type | Heavy Duty Power Connector Contact | |
| Series | Han D | |
| Current | 10A | |
| Accessory Type | Crimp Contact | |
| Contact Plating | Silver | |
| For Use With | Heavy Duty Power Connector | |
| Contact Material | Copper Alloy | |
| Termination Type | Crimp | |
| Voltage | 250V | |
| Minimum Wire Size mm² | 1.5mm² | |
| Standards/Approvals | No | |
| Gender | Female | |
| Maximum Wire Size mm² | 1.5mm² | |
| Alles selecteren | ||
|---|---|---|
Merk HARTING | ||
Product Type Heavy Duty Power Connector Contact | ||
Series Han D | ||
Current 10A | ||
Accessory Type Crimp Contact | ||
Contact Plating Silver | ||
For Use With Heavy Duty Power Connector | ||
Contact Material Copper Alloy | ||
Termination Type Crimp | ||
Voltage 250V | ||
Minimum Wire Size mm² 1.5mm² | ||
Standards/Approvals No | ||
Gender Female | ||
Maximum Wire Size mm² 1.5mm² | ||
Harting Han D Series Heavy Duty Power Connector Contact, 10A Current, 250V Voltage - 09150006201
This heavy-duty power connector contact is a female crimp contact intended for use in rugged industrial connectors. Designed for insertion into compatible heavy-duty housings, it provides a reliable conductive Interface for power distribution in automation and electrical systems while operating at rated voltages typical for industrial connectors.
Features & Benefits
• Rated for 10 A to support moderate current power circuits
• Works at 250V for standard industrial voltage applications
• Silver-plated copper alloy to reduce contact resistance
• Crimp termination enabling secure conductor attachment
• Suitable for 1.5 mm² conductors for AWG16 wiring systems
• Works at 250V for standard industrial voltage applications
• Silver-plated copper alloy to reduce contact resistance
• Crimp termination enabling secure conductor attachment
• Suitable for 1.5 mm² conductors for AWG16 wiring systems
**Applications**
• Suitable for heavy-duty connector assemblies in factory automation
• Ideal for electrical cabinets requiring removable power contacts
• Used with machinery connections where frequent mating is expected
• Can be used for industrial power distribution in control panels
• Ideal for electrical cabinets requiring removable power contacts
• Used with machinery connections where frequent mating is expected
• Can be used for industrial power distribution in control panels
What conductor size does the contact accept and how is it prepared?
It accepts a 1.5 mm² conductor and requires an 8mm insulation strip before crimp termination to achieve proper contact engagement.
How does the contact resist wear across repeated insertions?
The turned-contact design and silver plating support a minimum of 500 mating cycles while maintaining low contact resistance.
What are the electrical loss characteristics I can expect?
Contact resistance is specified at ≤3 mΩ, contributing to reduced voltage drop in power runs.
Are there any material restrictions relevant to recyclability or hazardous substances?
The contact is a copper alloy containing lead within a specified exemption and is listed for certain regulated substance notifications.
Note
Han-Com® inserts have mixed power and signal formats. A typical identifier is 4//2 which means there are 4 power contacts and 2 signal contacts. The current rating is different for each type of contact within a particular insert.
Approvals
UL, CSA, SEV
Warning
These connectors should not be mated or unmated under electrical load. Connectors of the same or different types arranged in a line should be polarised to prevent the possibility of wrong connection.
Gerelateerde Links
- HARTING Han D Female Crimp Contact, 10A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty
- HARTING Han Contacts Male Crimp Contact, 10A Minimum Wire Size 1.5 Maximum Wire Size 1.5 mm² for use with Heavy Duty
- HARTING Han Contacts Male Crimp Contact, 10A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty
- HARTING Han E Female Crimp Contact, 16A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty
- HARTING Han C Female Crimp Contact, 40A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty
- HARTING Han E Male Crimp Contact, 16A Minimum Wire Size 1.5 Maximum Wire Size 1.5 mm² for use with Heavy Duty Power
- HARTING Han E Male Crimp Contact, 16A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty Power
- HARTING Han D Male Crimp Contact, 10A Minimum Wire Size 1.5 mm² Maximum Wire Size 1.5 mm² for use with Heavy Duty Power