Alpha Wire Ecogen Ecowire Series Yellow 0.2 mm² Hook Up Wire, 24 AWG, 7, 30 m, Modified Polyphenilether, 6712 YL005
- RS-stocknr.:
- 687-7437
- Fabrikantnummer:
- 6712 YL005
- Fabrikant:
- Alpha Wire
Subtotaal (1 rol van 30 meter)*
€ 28,91
(excl. BTW)
€ 34,98
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 28,91 | € 0,964 |
*prijsindicatie
- RS-stocknr.:
- 687-7437
- Fabrikantnummer:
- 6712 YL005
- Fabrikant:
- Alpha Wire
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Alpha Wire | |
| Cross Sectional Area | 0.2mm² | |
| Product Type | Hook Up Wire | |
| Jacket Colour | Yellow | |
| American Wire Gauge | 24AWG | |
| Core Strands | 7 | |
| Cable Length | 30m | |
| Voltage | 600V | |
| Outside Diameter | 1.09mm | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Jacket Material | Modified Polyphenilether | |
| Sub Type | EcoWire | |
| Minimum Operating Temperature | -40°C | |
| Cable Type | Hookup | |
| Standards/Approvals | CE, CSA, UL | |
| Fire Behaviour | Halogen Free | |
| Series | Ecogen Ecowire | |
| Alles selecteren | ||
|---|---|---|
Merk Alpha Wire | ||
Cross Sectional Area 0.2mm² | ||
Product Type Hook Up Wire | ||
Jacket Colour Yellow | ||
American Wire Gauge 24AWG | ||
Core Strands 7 | ||
Cable Length 30m | ||
Voltage 600V | ||
Outside Diameter 1.09mm | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Jacket Material Modified Polyphenilether | ||
Sub Type EcoWire | ||
Minimum Operating Temperature -40°C | ||
Cable Type Hookup | ||
Standards/Approvals CE, CSA, UL | ||
Fire Behaviour Halogen Free | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 0.2mm² Cross Sectional Area, Yellow - 6712 YL001
This hook-up wire is a flexible single-core cable designed for general-purpose electrical connections in industrial and electronic systems. It provides insulated copper conductors for signal and power interconnections where a compact, colour-coded lead is required, and is suited to installations requiring elevated temperature performance.
Features & Benefits
• 0.2mm² conductor offers Compact cross section for tight routing
• 7-strand construction delivers enhanced flexibility for frequent movement
• 600Vrms rating allows use on low-voltage power and control circuits
• Temperature range -40°C to 105°C supports hot-environment operation
• VW-1 and IEC 60332-2 flame behaviour reduces fire spread risk
• Modified polyphenylene ether jacket provides halogen-free insulation
• 7-strand construction delivers enhanced flexibility for frequent movement
• 600Vrms rating allows use on low-voltage power and control circuits
• Temperature range -40°C to 105°C supports hot-environment operation
• VW-1 and IEC 60332-2 flame behaviour reduces fire spread risk
• Modified polyphenylene ether jacket provides halogen-free insulation
**Applications**
• Suitable for wiring control panels in automation equipment
• Ideal for internal wiring of electronic devices and instruments
• Used for field terminations in machinery harnesses
• Can be used for interconnects in electrical assemblies on machines
• Ideal for internal wiring of electronic devices and instruments
• Used for field terminations in machinery harnesses
• Can be used for interconnects in electrical assemblies on machines
What conductor composition ensures conductivity and pliability?
The conductor is copper MADE up of seven strands, combining electrical conductivity with improved flexibility compared with a solid core.
How is the product packaged for continuous installation runs?
It is supplied on spools offering continuous lengths such as 100 ft and 1,000 ft to aid uninterrupted cable pulls.
How does the insulation support regulatory and environmental requirements?
The jacket is halogen-free modified polyphenylene ether and the construction complies with relevant electrical safety and environmental directives listed in the specification.
What mechanical constraints should be observed during installation?
Maintain a minimum bend radius of 10x cable diameter and limit pull tension to the specified maximum to prevent conductor or insulation damage.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
Gerelateerde Links
- Alpha Wire Ecogen Ecowire Series Orange 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 OR005
- Alpha Wire Ecogen Ecowire Series Purple 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 VI005
- Alpha Wire Ecogen Ecowire Series Grey 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 SL005
- Alpha Wire Ecogen Ecowire Series Blue 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 BL005
- Alpha Wire Ecogen Ecowire Series Green 0.2 mm² Hook Up Wire 7 Modified Polyphenilether, 6712 GR005
- Alpha Wire Ecogen Ecowire Series Yellow 0.08 mm² Hook Up Wire 7 Modified Polyphenilether, 6710 YL005
- Alpha Wire Ecogen Ecowire Series Yellow 5.2 mm² Hook Up Wire 105 Modified Polyphenilether, 6719 YL005
- Alpha Wire Ecogen Ecowire Series Yellow 0.75 mm² Hook Up Wire 16 Modified Polyphenilether, 6715 YL005