Alpha Wire Ecogen Ecowire Series White 1.3 mm² Hook Up Wire, 16 AWG, 26, 305 m, Modified Polyphenylene Ether, 6716 WH001
- RS-stocknr.:
- 838-5113
- Fabrikantnummer:
- 6716 WH001
- Fabrikant:
- Alpha Wire
Subtotaal (1 rol van 305 meter)*
€ 363,62
(excl. BTW)
€ 439,98
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 4 stuk(s) vanaf 11 mei 2026
- Plus verzending 4 stuk(s) vanaf 11 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Rol(len) | Per rol | Per meter* |
|---|---|---|
| 1 + | € 363,62 | € 1,192 |
*prijsindicatie
- RS-stocknr.:
- 838-5113
- Fabrikantnummer:
- 6716 WH001
- Fabrikant:
- Alpha Wire
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Alpha Wire | |
| Cross Sectional Area | 1.3mm² | |
| Product Type | Hook Up Wire | |
| Jacket Colour | White | |
| American Wire Gauge | 16AWG | |
| Core Strands | 26 | |
| Cable Length | 305m | |
| Voltage | 600V | |
| Outside Diameter | 2.06mm | |
| Maximum Operating Temperature | 105°C | |
| Conductor Material | Copper | |
| Standards/Approvals | UL, CE, CSA | |
| Sub Type | Standard EcoWire | |
| Jacket Material | Modified Polyphenylene Ether | |
| Minimum Operating Temperature | -40°C | |
| Fire Behaviour | Flame Retardant | |
| Series | Ecogen Ecowire | |
| Alles selecteren | ||
|---|---|---|
Merk Alpha Wire | ||
Cross Sectional Area 1.3mm² | ||
Product Type Hook Up Wire | ||
Jacket Colour White | ||
American Wire Gauge 16AWG | ||
Core Strands 26 | ||
Cable Length 305m | ||
Voltage 600V | ||
Outside Diameter 2.06mm | ||
Maximum Operating Temperature 105°C | ||
Conductor Material Copper | ||
Standards/Approvals UL, CE, CSA | ||
Sub Type Standard EcoWire | ||
Jacket Material Modified Polyphenylene Ether | ||
Minimum Operating Temperature -40°C | ||
Fire Behaviour Flame Retardant | ||
Series Ecogen Ecowire | ||
Belden Ecogen Ecowire Series Hook Up Wire, 305m Cable Length, 1.3mm² Cross Sectional Area - 6716 WH001
This hook-up wire is a single-core, flexible conductor intended for internal wiring in control panels, appliances and industrial equipment. It is designed for environments requiring a Compact insulated conductor with a Durable polymer outer layer and elevated temperature tolerance for demanding electrical installations.
Features & Benefits
• 26-strand copper conductor delivers enhanced flexibility for tight routing
• 600V rated insulation supports robust low-voltage power distribution
• Modified polyphenylene ether jacket resists thermal and chemical exposure
• IEC 60332-1 flame retardant behaviour reduces vertical flame propagation risk
• Maximum operating temperature 105°C permits higher heat endurance
• Minimum operating temperature −40°C maintains pliability in cold conditions
• 600V rated insulation supports robust low-voltage power distribution
• Modified polyphenylene ether jacket resists thermal and chemical exposure
• IEC 60332-1 flame retardant behaviour reduces vertical flame propagation risk
• Maximum operating temperature 105°C permits higher heat endurance
• Minimum operating temperature −40°C maintains pliability in cold conditions
**Applications**
• Suitable for internal wiring of automation control panels
• Ideal for harnesses in electronic assemblies and devices
• Used with Terminal blocks and PCB connections in electrical cabinets
• Can be used for wiring in mechanical equipment with moderate vibration
• Used for retrofit and replacement wiring in industrial installations
• Ideal for harnesses in electronic assemblies and devices
• Used with Terminal blocks and PCB connections in electrical cabinets
• Can be used for wiring in mechanical equipment with moderate vibration
• Used for retrofit and replacement wiring in industrial installations
What conductor composition ensures flexibility for routing through assemblies?
The core comprises fine copper strands arranged into 26 individual filaments to give a balance of conductivity and manoeuvrability during installation.
How does the cable jacket influence long-term performance in equipment rooms?
The modified polyphenylene ether material provides thermal stability and resistance to many common solvents, helping maintain insulation integrity over extended service.
What approvals indicate acceptability for international electrical projects?
The product holds UL, CE and CSA recognitions, indicating conformity with multiple regional safety and performance assessment criteria.
What physical size should installers account for when planning bundle capacity?
The conductor and insulation assembly results in an overall outside diameter of 2.06mm for space planning and bundling considerations.
Standards
UL AWM 11028 VW-1, CSA AWM I A/B FT1, RoHS/RoHS2 Compliant, IEC 60332-2 Flame Behavior, REACH Compliant, CE Compliant
Gerelateerde Links
- Alpha Wire Ecogen Ecowire Series Orange 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716
- Alpha Wire Ecogen Ecowire Series Dark Blue Hook Up Wire 26 Modified Polyphenylene Ether, 6716 DB001
- Alpha Wire Ecogen Ecowire Series Red 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 RD001
- Alpha Wire Ecogen Ecowire Series Grey 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 SL005
- Alpha Wire Ecogen Ecowire Series Brown 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 BR005
- Alpha Wire Ecogen Ecowire Series Yellow 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 YL005
- Alpha Wire Ecogen Ecowire Series Slate 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 RD005
- Alpha Wire Ecogen Ecowire Series Blue 1.3 mm² Hook Up Wire 26 Modified Polyphenylene Ether, 6716 BL005