Fluke 1577 Insulation Tester, 500 V Min, 1000 V Max, 2 GΩ CAT III, CAT IV
- RS-stocknr.:
- 512-2802
- Fabrikantnummer:
- FLUKE-1577
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 1.097,00
(excl. BTW)
€ 1.327,37
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- 17 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.097,00 |
*prijsindicatie
- RS-stocknr.:
- 512-2802
- Fabrikantnummer:
- FLUKE-1577
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Model Number | 1577 | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 500V | |
| Maximum Test Voltage | 1000V | |
| Display Type | LCD | |
| Test Current | 1mA | |
| Battery Type | AA | |
| Battery Life | 1000h | |
| Power Source | Battery | |
| Minimum Operating Temperature | -20°C | |
| Insulation Testing Resistance | 2GΩ | |
| Maximum Operating Temperature | 55°C | |
| Safety Category Voltage | 1000V | |
| Safety Category Level | CAT III, CAT IV | |
| Standards/Approvals | No | |
| Height | 50mm | |
| Length | 203mm | |
| Weight | 550g | |
| Calibrated | UKAS | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Model Number 1577 | ||
Product Type Insulation Tester | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 500V | ||
Maximum Test Voltage 1000V | ||
Display Type LCD | ||
Test Current 1mA | ||
Battery Type AA | ||
Battery Life 1000h | ||
Power Source Battery | ||
Minimum Operating Temperature -20°C | ||
Insulation Testing Resistance 2GΩ | ||
Maximum Operating Temperature 55°C | ||
Safety Category Voltage 1000V | ||
Safety Category Level CAT III, CAT IV | ||
Standards/Approvals No | ||
Height 50mm | ||
Length 203mm | ||
Weight 550g | ||
Calibrated UKAS | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke Insulation Tester, 1000V Maximum Test Voltage, 0.1 MΩ to 600 MΩ Insulation Testing Resistance - FLUKE-1577
This insulation tester combines an electronic insulation tester and a true RMS digital multimeter in a single handheld instrument for fault finding and preventative maintenance in industrial settings. It is battery powered and designed to assess insulation resistance and standard electrical parameters while detecting live voltage to prevent unsafe insulation tests.
Features & Benefits
• Insulation resistance range 0.1MΩ–600MΩ provides wide diagnostic scope
• Test voltages 500V and 1000V enable standard insulation checks
• High test current 1mA supports accurate measurements at 1kΩ/V
• CAT IV 1000V insulation tester rating enhances on-site safety
• Battery life up to 1000 h reduces downtime during field work
• Large LCD display with backlight improves readability in low light
• Test voltages 500V and 1000V enable standard insulation checks
• High test current 1mA supports accurate measurements at 1kΩ/V
• CAT IV 1000V insulation tester rating enhances on-site safety
• Battery life up to 1000 h reduces downtime during field work
• Large LCD display with backlight improves readability in low light
Applications
• Suitable for maintenance of motors and generators
• Ideal for testing cable insulation in industrial installations
• Used for verifying switchgear insulation integrity
• Can be used for routine insulation checks on control panels
• Used with remote probe and clips for hard-to-reach connections
• Ideal for testing cable insulation in industrial installations
• Used for verifying switchgear insulation integrity
• Can be used for routine insulation checks on control panels
• Used with remote probe and clips for hard-to-reach connections
How does it prevent performing an insulation test on live circuits?
It detects voltages above 30V and inhibits insulation testing when such voltage is present to protect users and equipment.
What power source and battery type does it require for field operation?
It operates from alkaline cells and is specified to perform extensive meter and insulation testing on fresh batteries.
What safety and measurement standards are applicable to its design?
It meets IEC 61010-1 safety requirements and is rated for CAT III and CAT IV measurement categories at specified voltages.
How robust is it for workshop and site use regarding ingress protection and storage?
It is supplied in a rugged hard case and its environmental limits include wide operating and storage temperature ranges suitable for varied conditions.
Gerelateerde Links
- Fluke 1577 Insulation Tester 1000 V Max CAT III, CAT IV
- Fluke 1507 Insulation Tester 1000 V Max CAT III, CAT IV
- Fluke 1587 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1587 FC Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1503 Insulation Tester 1000 V Max CAT III
- Fluke 1555 Insulation Tester 10000 V Max CAT IV, CAT III
- Fluke 1550C Insulation Tester 5000 V Max CAT IV, CAT III
- Fluke 1550C FC Insulation Tester 5000 V Max CAT III, CAT IV