Fluke 1507 Insulation Tester, 50 V Min, 1000 V Max, 10 GΩ CAT III, CAT IV
- RS-stocknr.:
- 528-9321
- Fabrikantnummer:
- F-1507
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 783,00
(excl. BTW)
€ 947,43
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- Plus verzending 92 stuk(s) vanaf 23 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 783,00 |
*prijsindicatie
- RS-stocknr.:
- 528-9321
- Fabrikantnummer:
- F-1507
- Fabrikant:
- Fluke
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Product Type | Insulation Tester | |
| Model Number | 1507 | |
| Tester Type | Insulation Tester | |
| Minimum Test Voltage | 50V | |
| Maximum Test Voltage | 1000V | |
| Display Type | LCD | |
| Test Current | 1mA | |
| Power Source | Battery | |
| Battery Type | AA | |
| Insulation Testing Resistance | 10GΩ | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 50°C | |
| Safety Category Level | CAT III, CAT IV | |
| Safety Category Voltage | 600V | |
| Height | 50mm | |
| Standards/Approvals | No | |
| Length | 203mm | |
| Calibrated | RSCAL | |
| Weight | 550g | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Product Type Insulation Tester | ||
Model Number 1507 | ||
Tester Type Insulation Tester | ||
Minimum Test Voltage 50V | ||
Maximum Test Voltage 1000V | ||
Display Type LCD | ||
Test Current 1mA | ||
Power Source Battery | ||
Battery Type AA | ||
Insulation Testing Resistance 10GΩ | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 50°C | ||
Safety Category Level CAT III, CAT IV | ||
Safety Category Voltage 600V | ||
Height 50mm | ||
Standards/Approvals No | ||
Length 203mm | ||
Calibrated RSCAL | ||
Weight 550g | ||
Vrijgesteld
- Land van herkomst:
- CN
Fluke Insulation Tester, 1000V Maximum Test Voltage, 20Ω to 20TΩ Insulation Testing Resistance - FLUKE 1507
This insulation tester is a Compact handheld instrument designed for electrical contractors, industrial and commercial electricians to perform insulation resistance measurements, troubleshooting, commissioning and preventative maintenance. It offers selectable test voltages for a range of insulation checks and includes safety features to prevent testing on live circuits, making it suitable for on-site fieldwork and workshop use.
Features & Benefits
• Multiple selectable test voltages up to 1000V for varied insulation tasks
• Measures 0.01 MΩ to 10 GΩ to assess a wide resistance range
• 1 mA nominal short-circuit current for accurate high-voltage tests
• Live-circuit detection inhibits tests above 30V for operator safety
• Large backlit LCD for clear readings in low light
• Runs on four AA batteries enabling portable field use
• Measures 0.01 MΩ to 10 GΩ to assess a wide resistance range
• 1 mA nominal short-circuit current for accurate high-voltage tests
• Live-circuit detection inhibits tests above 30V for operator safety
• Large backlit LCD for clear readings in low light
• Runs on four AA batteries enabling portable field use
Applications
• Suitable for commissioning motor windings and cable insulation
• Ideal for preventative maintenance in industrial installations
• Used for insulation checks on control panels and switchgear
• Can be used for solar array troubleshooting and verification
• Suitable for earth-bond continuity and low-ohm checks during installations
• Ideal for preventative maintenance in industrial installations
• Used for insulation checks on control panels and switchgear
• Can be used for solar array troubleshooting and verification
• Suitable for earth-bond continuity and low-ohm checks during installations
How does the instrument protect the user when testing capacitive circuits?
It auto-discharges capacitive voltage in under 0.5 s for a 1 μF load or less to remove stored charge prior to handling.
What voltage and resistance measurement ranges are available beyond insulation tests?
It measures AC/DC voltage from 0.1V to 600V and resistance from 0.01 Ω to 20.00 kΩ for general diagnostic tasks.
What environmental limits affect on-site operation?
Operating temperature is -20 °C to 55 °C with specified relative humidity limits reducing accuracy above 30 °C
storage extends to -40 °C to 60 °C.
What safety and certification details apply to high-voltage use?
The instrument is rated for measurement category IV at 600V and holds CSA certification for adherence to safety standards.
Which accessories assist repetitive or hard-to-reach testing?
A remote probe, test leads, probes and crocodile clips are supplied to simplify repeated measurements and reach awkward locations.
Supplied with
The Fluke 1507 tester comes with remote probe, test leads, test probes, alligator clips, user documentation
Gerelateerde Links
- Fluke 1507 Insulation Tester 1000 V Max CAT III, CAT IV
- Fluke 1577 Insulation Tester 1000 V Max CAT III, CAT IV
- Fluke 1587 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1587 FC Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1503 Insulation Tester 1000 V Max CAT III
- Fluke 1555 Insulation Tester 10000 V Max CAT IV, CAT III
- Fluke 1550C Insulation Tester 5000 V Max CAT IV, CAT III
- Fluke 1550C FC Insulation Tester 5000 V Max CAT III, CAT IV