Siemens 4-Pole Panel Mount Non-Fused Switch Disconnector -, IP65, 32A, 11.5 kW

Subtotaal (1 eenheid)*

€ 97,47

(excl. BTW)

€ 117,94

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 1 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 97,47

*prijsindicatie

RS-stocknr.:
239-2640
Fabrikantnummer:
3LD2213-1TL53
Fabrikant:
Siemens
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Siemens

Product Type

Non-Fused Switch Disconnector

Number of Poles

4

Mount Type

Panel Mount

IP Rating

IP65

Handle Colour

Red, Yellow

Switching Current

32A

Series

SENTRON 3LD

Auxiliary Contacts Available

No

Switching AC Voltage

400V ac

Minimum Operating Temperature

-25°C

Switching Power

11.5kW

Maximum Operating Temperature

55°C

Hazardous Area Certification

NO

Standards/Approvals

CCC

Land van herkomst:
DE

Siemens SENTRON 3LD Series Non-Fused Switch Disconnector, 32A Switching Current, IP65 - 3LD2213-1TL53


This non-fused switch disconnector provides a robust means of isolating electrical circuits in industrial settings, offering visible manual on/off operation with a rotary red/yellow handle and floor mounting with door coupling. It is designed for use as a main switch, emergency-off and maintenance isolator in control and power distribution environments, delivering safe manual interruption for three-phase systems and motor loads.

Features & Benefits


• Four-pole design enabling full NEUTRAL and phase isolation
• Rated operational current 32A for heavy-duty circuit control
• Switching power 11.5kW at AC-23A 400V for motor isolation
• IP65 front protection for weatherproof outdoor use
• Box Terminal connection for secure conductor termination
• Mechanical endurance 100000 cycles for long service life

Applications


• Suitable for isolating three-phase motors in manufacturing plants
• Ideal for switchgear doors with floor-mounted coupling arrangements
• Used for maintenance isolation of distribution boards
• Suitable for outdoor installations requiring weatherproof protection
• Can be used for emergency-off points on production lines

What temperatures can it operate within?


It functions reliably between -25°C and 55°C to accommodate factory and outdoor ambient ranges.

How is the device secured against unauthorised switching?


The handle can be locked in the OFF position using hasp brackets accommodating 4 to 8mm thickness.

What conductor types and sizes can be connected?


Main conductors may be solid or stranded copper from 1.5mm² up to 16mm² with appropriate termination

auxiliary connections accept smaller cross-sections as specified.

How does it behave under short-circuit conditions?


With a suitable upstream gL/gG fuse it permits conditional short-circuit current coordination up to the specified fuse limits and defined let-through currents.

Is it suitable for panel mounting and what fixing methods are available?


It is a fixed-mounted device supporting 4-hole front mounting and rail mounting for integration into switchgear assemblies.

Gerelateerde Links