Flowline EchoSwitch Series Ultrasonic Level Switch Ultrasonic Level Sensor, Vertical, Fluorelastomer, Housing

Subtotaal (1 eenheid)*

€ 1.234,02

(excl. BTW)

€ 1.493,16

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Tijdelijk niet op voorraad
  • Verzending vanaf 26 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 1.234,02

*prijsindicatie

RS-stocknr.:
124-0131
Fabrikantnummer:
LU74-5004
Fabrikant:
Flowline
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Flowline

Device Type

Ultrasonic Level Switch

Product Type

Ultrasonic Level Sensor

Mount Type

Vertical

Housing Material

Polycarbonate

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

71°C

Maximum AC Voltage

250V ac

Maximum Current

20mA

Maximum Pressure

2bar

Gasket Material

Fluorelastomer

Standards/Approvals

CE

Hazardous Area Certification

No

Series

EchoSwitch

Land van herkomst:
US

Flowline Ultrasonic Level Switch


The Flowline Ultrasonic level sensor provides continuous level detection up to 26.2ft (8m) with 3 programmable relays for level switch or level control functions and a 4mA to 20mA signal output. This sensor is programmed via the integral push button display module. Each relay can be configured on a single set point (high-level alarm or low-level alarm) or latched on two set points for automatic fill or empty in simplex (one pump or valve), duplex (two pumps) or triplex (three pumps) level control modes with selectable time delay and fail-safe logic. The embedded level controller can lower cost by replacing external control hardware. This non-contact liquid level sensor is ideally suited for corrosive, sticky or dirty liquids.

Note:

Compatible with Various Flowline product ranges such as DataLoop, DataView, DataPoint and Commander

Features and Benefits


Configuration is simple via an integral push button display module

Three programmable relays for switch, pump control and fail-safety

1 pump or valve with 2 alarms

2 pumps (lead-lag) with 1 alarms

2 pumps (duplexing) with 1 alarms

3 independent switch point alarms

LCD display indicates level height in engineering units and relay status

Narrow 2in or 3in beam width for applications with limited measurement space

Short 4in or 8in dead band maximizes the measurable filling capacity of the tank

PVDF transducer and NEMA 4X polycarbonate enclosure for corrosive liquids

Automatic temperature compensation for accurate measurement

Sensor range/size 5.5m (18.0ft)

Process mount: 2in NPT (2in G)

Maximum current of 20mA

Current rating of 2A

Applications


Tanks

Skids

IBC

Sumps and process tank level applications

Certifications


CE certified

ANSI/ESD S20.20:2014

BS EN 61340-5-1:2007

Gerelateerde Links