Honeywell Technologies GLA Series Roller Lever Limit Switch, 1 NC/1 NO, IP67, Die Cast Zinc Housing, 600V ac, 6A
- RS-stocknr.:
- 186-8201
- Artikelnummer Distrelec:
- 136-30-805
- Fabrikantnummer:
- GLAC01A1B
- Fabrikant:
- Honeywell Technologies
Subtotaal (1 eenheid)*
€ 265,37
(excl. BTW)
€ 321,10
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 4 stuk(s) klaar voor verzending
- 105 stuk(s) klaar voor verzending vanaf een andere locatie
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 265,37 |
*prijsindicatie
- RS-stocknr.:
- 186-8201
- Artikelnummer Distrelec:
- 136-30-805
- Fabrikantnummer:
- GLAC01A1B
- Fabrikant:
- Honeywell Technologies
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Honeywell Technologies | |
| Product Type | Limit Switch | |
| Actuator Type | Roller Lever | |
| Contact Configuration | 1 NC/1 NO | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Terminal Type | M20 | |
| Switching Current | 6A | |
| Series | GLA | |
| Switching AC Voltage | 600V ac | |
| Switching DC Voltage | 250V dc | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Length | 145.8mm | |
| Standards/Approvals | UL, CSA, CE, CCC | |
| Depth | 42mm | |
| Width | 42mm | |
| Hazardous Area Certification | No | |
| Conduit Entry | 20 mm | |
| Operating Force | 0.33Nm | |
| Mechanical Life | 15000000Operations | |
| Mounting Orientation | Side | |
| Alles selecteren | ||
|---|---|---|
Merk Honeywell Technologies | ||
Product Type Limit Switch | ||
Actuator Type Roller Lever | ||
Contact Configuration 1 NC/1 NO | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Terminal Type M20 | ||
Switching Current 6A | ||
Series GLA | ||
Switching AC Voltage 600V ac | ||
Switching DC Voltage 250V dc | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Length 145.8mm | ||
Standards/Approvals UL, CSA, CE, CCC | ||
Depth 42mm | ||
Width 42mm | ||
Hazardous Area Certification No | ||
Conduit Entry 20 mm | ||
Operating Force 0.33Nm | ||
Mechanical Life 15000000Operations | ||
Mounting Orientation Side | ||
- Land van herkomst:
- GB

Honeywell GLA Series Limit Switch, 20mm Conduit Entry, 1 NC/1 NO Contact Configuration - GLAC01A1B
Features and Benefits:
• 1NC and 1NO contact arrangement allows versatile circuit control
• Rated for 600V AC and 250V DC to handle varied supply voltages
• IP67 protection permits use in dusty and water-exposed locations
• Mechanical life of 15,000,000 operations supports long service cycles
• Operating range from -25 to 85°C maintains function across climates
Applications
• Ideal for limit sensing on robotic pick-and-place assemblies
• Used with motor starters to detect shaft or cam position
• Can be used for safety interlocks on access panels and guards
• Suitable for automated packaging machinery position feedback
What conduit connection does it accept for cable entry?
How is the actuator configured for side installation?
What is the required actuation effort to operate the mechanism?
Which standards has the product been approved against?
Can it be used in certified hazardous-area installations?
Approvals
Warning
Standards
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and controlgear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLC and GLD limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Gerelateerde Links
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Adjustable Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Roller Lever Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
- Honeywell Technologies GLA Series Plunger Limit Switch IP67 600V ac, 6A
