Telemecanique Sensors XCKP Series Plunger Limit Switch, 1 NO/1 NC, IP67, IP66, Plastic Housing, 240V ac, 10A
- RS-stocknr.:
- 195-1682
- Fabrikantnummer:
- XCKP2510G11
- Fabrikant:
- Telemecanique Sensors
Subtotaal (1 eenheid)*
€ 38,10
(excl. BTW)
€ 46,10
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 18 stuk(s) vanaf 12 oktober 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 38,10 |
*prijsindicatie
- RS-stocknr.:
- 195-1682
- Fabrikantnummer:
- XCKP2510G11
- Fabrikant:
- Telemecanique Sensors
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Telemecanique Sensors | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP67, IP66 | |
| Housing Material | Plastic | |
| Contact Type | Slow Break | |
| Switching Current | 10A | |
| Terminal Type | Screw Clamp | |
| Series | XCKP | |
| Minimum Operating Temperature | -25°C | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 240V ac | |
| Maximum Operating Temperature | 70°C | |
| Depth | 65mm | |
| Length | 31mm | |
| Width | 30mm | |
| Standards/Approvals | RoHS | |
| Hazardous Area Certification | No | |
| Mounting Orientation | Cable | |
| Mechanical Life | 15000000Cycles | |
| Operating Force | 45N | |
| Conduit Entry | M20 | |
| Alles selecteren | ||
|---|---|---|
Merk Telemecanique Sensors | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP67, IP66 | ||
Housing Material Plastic | ||
Contact Type Slow Break | ||
Switching Current 10A | ||
Terminal Type Screw Clamp | ||
Series XCKP | ||
Minimum Operating Temperature -25°C | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 240V ac | ||
Maximum Operating Temperature 70°C | ||
Depth 65mm | ||
Length 31mm | ||
Width 30mm | ||
Standards/Approvals RoHS | ||
Hazardous Area Certification No | ||
Mounting Orientation Cable | ||
Mechanical Life 15000000Cycles | ||
Operating Force 45N | ||
Conduit Entry M20 | ||
- Land van herkomst:
- ID
Telemecanique Sensors XCKP Series Limit Switch, IP67, 10A Switching Current - XCKP2510G11
This limit switch is a plunger-operated device designed to detect mechanical position changes and provide switching for control systems in industrial environments. It is housed in plastic with cable mounting orientation and offers a slow-break contact arrangement to manage switching tasks across DC and AC circuits while operating across a broad temperature range.
Features and Benefits:
• IP67 and IP66 protection for use in wet environments
• 1NO/1NC slow-break contacts for controlled switching behaviour
• 10A switching current to handle moderate load circuits
• 240V AC and 250V DC switching capability for mixed systems
• Operating force 45N to ensure consistent actuation response
• Mechanical life 15,000,000 cycles for extended operational durability
• 1NO/1NC slow-break contacts for controlled switching behaviour
• 10A switching current to handle moderate load circuits
• 240V AC and 250V DC switching capability for mixed systems
• Operating force 45N to ensure consistent actuation response
• Mechanical life 15,000,000 cycles for extended operational durability
Applications
• Suitable for conveyor end-of-travel detection
• Ideal for machine tool position feedback
• Used with actuators in assembly automation
• Can be used for safety interlock monitoring
• Suitable for panel-mounted control signal input
• Ideal for machine tool position feedback
• Used with actuators in assembly automation
• Can be used for safety interlock monitoring
• Suitable for panel-mounted control signal input
What Terminal arrangement does it provide for wiring?
It uses screw-clamp terminals to secure conductor connections.
How is the conduit or cable routed into the enclosure?
Entry is provided via an M20 conduit Interface for gland or conduit attachment.
What temperature extremes can it operate within?
The device functions across a range from -25°C to 70°C.
What contact behaviour should be expected during switching?
Contacts operate as slow-break type, reducing arcing on opening.
Is it certified for use in explosive atmospheres?
It does not carry hazardous area certification.
Gerelateerde Links
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP66 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Roller Plunger Limit Switch IP67 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Roller Plunger Limit Switch IP66 Plastic Housing 10A
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP67 Plastic Housing 3A
- Telemecanique Sensors XCKP Series Plunger Limit Switch IP66 Plastic Housing 3A
- Telemecanique Sensors XCKP Series Roller Plunger Limit Switch IP66 Plastic Housing 3A