Honeywell GLB Series Rod Limit Switch, 1 NO/1 NC, IP67, Die Cast Zinc Housing, 600V ac, 10A
- RS-stocknr.:
- 207-1997
- Fabrikantnummer:
- GLBC02A2B
- Fabrikant:
- Honeywell
Subtotaal (1 eenheid)*
€ 293,28
(excl. BTW)
€ 354,87
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 10 stuk(s) vanaf 01 juni 2026
- Plus verzending 12 stuk(s) vanaf 27 juli 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 293,28 |
*prijsindicatie
- RS-stocknr.:
- 207-1997
- Fabrikantnummer:
- GLBC02A2B
- Fabrikant:
- Honeywell
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Honeywell | |
| Actuator Type | Rod | |
| Product Type | Limit Switch | |
| Contact Configuration | 1 NO/1 NC | |
| IP Rating | IP67 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 10A | |
| Terminal Type | M20 | |
| Series | GLB | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 600V ac | |
| Minimum Operating Temperature | -25°C | |
| Maximum Operating Temperature | 85°C | |
| Standards/Approvals | CCC, CE, CSA, UL | |
| Width | 42mm | |
| Length | 145.8mm | |
| Depth | 55.9mm | |
| Hazardous Area Certification | No | |
| Operating Force | 0.33Nm | |
| Mounting Orientation | Standard | |
| Conduit Entry | 20 mm | |
| Mechanical Life | 15000000Operations | |
| Alles selecteren | ||
|---|---|---|
Merk Honeywell | ||
Actuator Type Rod | ||
Product Type Limit Switch | ||
Contact Configuration 1 NO/1 NC | ||
IP Rating IP67 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 10A | ||
Terminal Type M20 | ||
Series GLB | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 600V ac | ||
Minimum Operating Temperature -25°C | ||
Maximum Operating Temperature 85°C | ||
Standards/Approvals CCC, CE, CSA, UL | ||
Width 42mm | ||
Length 145.8mm | ||
Depth 55.9mm | ||
Hazardous Area Certification No | ||
Operating Force 0.33Nm | ||
Mounting Orientation Standard | ||
Conduit Entry 20 mm | ||
Mechanical Life 15000000Operations | ||
- Land van herkomst:
- GB


Honeywell GLB Series Limit Switch, 20mm Conduit Entry, 1 NO/1 NC Contact Configuration - GLBC02A2B
This limit switch provides position detection for industrial automation and control systems, offering a rugged control input for mechanical processes. It is designed for straightforward installation in demanding environments where a rod-type actuator is required, delivering snap-action electrical signalling for machine control and safety interlocks.
Features and Benefits:
• Electrostatic epoxy-coated zinc housing for corrosion resistance and longevity
• 1 NO 1 NC snap-action contacts rated for 600V and 10 A for heavy-duty switching
• IP67 ingress protection enabling use in wet and dusty conditions
• Mechanical life of 15,000,000 operations for sustained cycling applications
• Operating temperature range −25 to 85 °C for wide environmental tolerance
• Low operating torque of 0.33 N·m for reduced actuation force requirements
• 1 NO 1 NC snap-action contacts rated for 600V and 10 A for heavy-duty switching
• IP67 ingress protection enabling use in wet and dusty conditions
• Mechanical life of 15,000,000 operations for sustained cycling applications
• Operating temperature range −25 to 85 °C for wide environmental tolerance
• Low operating torque of 0.33 N·m for reduced actuation force requirements
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for plunger- or cam-actuated machine safety interlocks
• Used with packaging equipment for repetitive position sensing
• Can be used for valve position feedback in process plants
• Used for indexing control on automated assembly machinery
• Ideal for plunger- or cam-actuated machine safety interlocks
• Used with packaging equipment for repetitive position sensing
• Can be used for valve position feedback in process plants
• Used for indexing control on automated assembly machinery
What conduit size does it accept for cable entry?
The enclosure accommodates an M20 conduit entry to suit standard industrial trunking.
How does the actuator type affect mounting choices?
The rod actuator provides linear contact with moving parts and permits side or end actuation in standard mounting orientations.
What materials constitute the enclosure to withstand industrial wear?
The body is MADE from zinc with an electrostatic epoxy coating to reduce corrosion and surface wear.
Which electrical standards does it comply with for safety and interoperability?
It is approved to CE, UL, CSA and CCC standards for international installation requirements.
Approvals
UL/ UL listed for Canada
Standards
IEC/EN 60947-5-1
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and control gear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLB limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
While IEC/EN 609747-1 covers general rules relating to low voltage switchgear and control gear, IEC/EN 60947-5-1 specifically relates to control circuit devices and switching elements. The standard monitors the characteristics of devices, the electrical and mechanical requirements and the functional requirements.
EN50047
GLB limit switches are constructed from housing that meets EN50047. EN50047 applies to position switches with an automatic return actuator. Models that meet EN50047 feature standardised characteristics and dimensions (30.5 x 31.1 x 68 mm).
IP 66
A rating of IP 66 ensures that the limit switch units are protected against dust and low-pressure jets of water.
Sealed to NEMA 1, 4, 12, 13
NEMA 1 states that enclosures can be used indoor and offers a degree of protection against contact with the equipment enclosed.
NEMA 4 states that enclosures can be used either indoor or outdoor and provide protection against windblown rain and dust, hose directed water and splashing water.
NEMA 12 states that enclosures are intended for use indoors and offer some protection from dust, dirt, falling dirt and dripping non-corrosive liquids.
NEMA 13 states that enclosures are used indoors and offer a level of protection from oil, non-corrosive coolants, spraying water and dust.
Gerelateerde Links
- Honeywell GLB Series Rod Limit Switch IP67 600V ac, 10A
- Honeywell GLB Series Roller Lever Limit Switch IP67 600V ac, 10A
- Honeywell GLB Series Plunger Limit Switch IP67 600V ac, 10A
- Honeywell GLB Series Roller Lever Limit Switch IP67 600V ac, 10A
- Honeywell GLB Series Coil Spring Limit Switch IP67 Die Cast Zinc Housing 10A Max
- Honeywell Roller Lever Limit Switch IP67 600V ac, 10A
- Honeywell Roller Lever Limit Switch IP66 Die Cast Zinc Housing 10A
- Honeywell GLA Series Roller Lever Limit Switch IP67 600V ac, 10A