Honeywell Technologies GXA Series Plunger Limit Switch, 1 NC/1 NO, IP67, IP66, Die Cast Zinc Housing, 250V ac, 4A
- RS-stocknr.:
- 396-2535
- Fabrikantnummer:
- GXA51B
- Fabrikant:
- Honeywell
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 1.051,38
(excl. BTW)
€ 1.272,17
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 5 stuk(s) vanaf 14 september 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 1.051,38 |
*prijsindicatie
- RS-stocknr.:
- 396-2535
- Fabrikantnummer:
- GXA51B
- Fabrikant:
- Honeywell
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Honeywell | |
| Product Type | Limit Switch | |
| Actuator Type | Plunger | |
| Contact Configuration | 1 NC/1 NO | |
| IP Rating | IP67, IP66 | |
| Housing Material | Die Cast Zinc | |
| Contact Type | Snap Action | |
| Switching Current | 4A | |
| Terminal Type | Cable | |
| Series | GXA | |
| Switching DC Voltage | 250V dc | |
| Switching AC Voltage | 250V ac | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 75°C | |
| Standards/Approvals | CE/EN/IEC | |
| Length | 102.9mm | |
| Width | 42mm | |
| Depth | 62.4mm | |
| Hazardous Area Certification | ATEX | |
| Operating Force | 16N | |
| Mechanical Life | 2000000Operations | |
| Alles selecteren | ||
|---|---|---|
Merk Honeywell | ||
Product Type Limit Switch | ||
Actuator Type Plunger | ||
Contact Configuration 1 NC/1 NO | ||
IP Rating IP67, IP66 | ||
Housing Material Die Cast Zinc | ||
Contact Type Snap Action | ||
Switching Current 4A | ||
Terminal Type Cable | ||
Series GXA | ||
Switching DC Voltage 250V dc | ||
Switching AC Voltage 250V ac | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 75°C | ||
Standards/Approvals CE/EN/IEC | ||
Length 102.9mm | ||
Width 42mm | ||
Depth 62.4mm | ||
Hazardous Area Certification ATEX | ||
Operating Force 16N | ||
Mechanical Life 2000000Operations | ||
- Land van herkomst:
- GB




Honeywell GXA Series Limit Switch, IP67, 16N Operating Force - GXA51B
This limit switch provides position sensing for industrial control systems, using a plunger actuator with snap-action contacts. It is designed for harsh environments, offering protection against ingress and certified for use in potentially explosive atmospheres. The device connects via a cable Terminal and is intended for repetitive mechanical switching duties in automation and electrical installations.
Features and Benefits:
• Snap-action contacts rated 4A enabling rapid, reliable switching
• Operating force 16N for consistent actuation without excessive load
• Mechanical life 2 million operations supporting long service intervals
• Temperature range -20°C to 75°C suitable for varied thermal conditions
• Housing of die-cast zinc providing robust enclosure integrity
• IP66 and IP67 ingress protection allowing temporary immersion and jet cleaning
• Operating force 16N for consistent actuation without excessive load
• Mechanical life 2 million operations supporting long service intervals
• Temperature range -20°C to 75°C suitable for varied thermal conditions
• Housing of die-cast zinc providing robust enclosure integrity
• IP66 and IP67 ingress protection allowing temporary immersion and jet cleaning
Applications
• Suitable for conveyor end-of-travel detection in manufacturing lines
• Ideal for position feedback on industrial valves and actuators
• Used for safety interlock sensing in hazardous-area installations
• Can be used for limit detection on automated handling equipment
• Ideal for position feedback on industrial valves and actuators
• Used for safety interlock sensing in hazardous-area installations
• Can be used for limit detection on automated handling equipment
What electrical voltages can the switch handle for AC and DC supplies?
It switches up to 250V for both AC and DC circuits with a maximum current of 4 A.
How is the unit terminated for wiring in panels or machines?
Electrical connection is provided via an integral cable Terminal for direct cabling.
What approvals ensure suitability for European installations?
The unit meets CE and EN/IEC standards and carries ATEX hazardous-area certification.
How Compact is the enclosure for panel or machine integration?
The body measures 102.9mm in length, 42mm in width and 62.4mm in depth for space planning.
Group and Category
II 2 G EEx d IIC T6
Certificate No.
KEMA 00 ATEX 2103X
Approvals
II 2 G EEx d IIC T6
Warning
GXA limit switches are not safety devices. They should be not used as emergency stop or safety devices. They must not be used in applications where personal injury could occur as a result of product failure.
Standards
ATEX (CE), IEC Ex
Shock resistant to IEC 60068-2-27 standard.
Vibration resistant to IEC 60068-2-6 standard.
II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C.
KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X.
Conforms to EN60079-0, EN60079-1, EN61241-0, EN61241-1.
CE marked.
Shock resistant to IEC 60068-2-27 standard.
Vibration resistant to IEC 60068-2-6 standard.
II 2 G Ex d IIC T6, II 2 D Ex tD A21 IP66 T85°C.
KEMA 00 ATEX 2103 X, IEC Ex KEM 10.0039X.
Conforms to EN60079-0, EN60079-1, EN61241-0, EN61241-1.
CE marked.
Gerelateerde Links
- Honeywell Technologies GXA Series Side Rotary Limit Switch Die Cast Zinc Housing 4A
- Honeywell Technologies Plunger Limit Switch IP66 IP68, Die Cast Zinc Housing
- Honeywell Technologies Top Plunger Limit Switch IP66, Die Cast Zinc Epoxy Coated Housing
- Honeywell Technologies 914CE Series Plunger Limit Switch IP67 Die Cast Zinc Housing
- Honeywell Technologies BZE6 Series Plunger Limit Switch IP66 600V
- Honeywell Technologies Plunger Limit Switch IP67 300V ac
- Honeywell Technologies BZE6 Series Pin Plunger Limit Switch IP66 600V
- Honeywell Technologies BZE6 Series Plunger Limit Switch IP66 600V, 15A
