ABB System Pro M Compact S200 Miniature Circuit Breaker, 3-Pole, 1.6 A, Type D, 400 V ac AC, 20 kA Breaking Capacity

Subtotaal (1 eenheid)*

€ 179,53

(excl. BTW)

€ 217,23

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Voorradig bij de fabrikant
  • Klaar voor verzending vanaf 04 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 179,53

*prijsindicatie

RS-stocknr.:
237-3248
Fabrikantnummer:
2CDS253001R0971
Fabrikant:
ABB
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

ABB

Number of Poles

3

Product Type

Miniature Circuit Breaker

Tripping Characteristics

Type D

Breaking Capacity

20kA

Mount Type

DIN Rail

Range

System Pro M Compact

Series

S200

Terminal Type

Screw

IP Rating

IP20

Height

88mm

Standards/Approvals

UL1077, IEC/EN 60947-2, IEC/EN 60898-1

Depth

69mm

Tripping Mechanism

Thermal, Electromechanic

Land van herkomst:
DE

ABB S200 Series Miniature Circuit Breaker, 1.6A Current, 400V AC Rated AC Voltage - 2CDS253001R0971


This miniature circuit-breaker provides three-pole overcurrent protection for electrical distribution installed on DIN rails. It combines a delayed thermal element for overloads with an electromechanical release for short circuits, delivering selective interruption in residential, commercial and industrial switchboards while offering Visual on/off indication.

Features & Benefits


• 6kA breaking capacity for secure fault interruption
• Type D trip characteristic suited to high inrush loads
• Thermal and electromechanical tripping for dual protection
• Screw terminals enabling robust conductor connection
• Energy-limiting class 3 to reduce let-through energy
• 20,000 electrical endurance cycles for sustained operation

Applications


• Suitable for motor circuits with high-start currents
• Ideal for distribution boards in commercial buildings
• Used for protection in automation control panels
• Can be used for three-phase lighting and heating circuits

What electrical voltages can it handle in typical installations?


It is designed for rated operation at 400V AC and withstands up to 440V in specified test conditions.

How does the device indicate switching state to installers?


A red/green marker shows ON or OFF positions for quick Visual confirmation.

What mounting method and Terminal style are required for installation?


The unit clips onto TH35 DIN rails and uses screw-type terminals with a 2.8 N·m recommended tightening torque.

What environmental temperatures are permitted during operation?


The allowable ambient range for operation is between −25°C and +55°C.

What mechanical and electrical life can be expected under rated use?


It offers 20,000 mechanical cycles and 20,000 electrical cycles at rated conditions.

Gerelateerde Links