Lovato ModuLo P1MB MCB, 2P, 2A Curve D, 230V AC, 80V DC, 10 kA Breaking Capacity
- RS-stocknr.:
- 825-5744
- Fabrikantnummer:
- P1MB2PD02
- Fabrikant:
- Lovato
Subtotaal (1 eenheid)*
€ 43,05
(excl. BTW)
€ 52,09
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- Plus verzending 51 stuk(s) vanaf 05 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 43,05 |
*prijsindicatie
- RS-stocknr.:
- 825-5744
- Fabrikantnummer:
- P1MB2PD02
- Fabrikant:
- Lovato
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Lovato | |
| Number of Poles | 2 | |
| Current Rating | 2A | |
| Tripping Characteristics | Type D | |
| Rated AC Voltage | 230 V, 400V | |
| Rated DC Voltage | 80V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | ModuLo | |
| Series | P1MB | |
| Circuit Breaker Type | MCB | |
| Width | 36mm | |
| Length | 86.5mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Alles selecteren | ||
|---|---|---|
Merk Lovato | ||
Number of Poles 2 | ||
Current Rating 2A | ||
Tripping Characteristics Type D | ||
Rated AC Voltage 230 V, 400V | ||
Rated DC Voltage 80V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range ModuLo | ||
Series P1MB | ||
Circuit Breaker Type MCB | ||
Width 36mm | ||
Length 86.5mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
N.v.t.
- Land van herkomst:
- IT
Lovato P1MB Series MCB, 2A, 10kA Breaking Capacity (at Maximum Voltage Rating) - P1MB2PD02
This MCB provides critical protection against overloads and short circuits in electrical systems. It is compatible with a wide range of applications, effectively regulating electrical flow while safeguarding connected devices. Its specifications make it a suitable option for professionals in automation and electronics.
Features & Benefits
• Current rating of 2A for effective load management
• Type D MCB suitable for high inrush current applications
• Rated for 230V and 400V, adaptable to various systems
• 10 kA breaking capacity for enhanced safety and reliability
• Easy installation on DIN rails for diverse setups
• IP20 terminal protection for added safety against accidental contact
• Type D MCB suitable for high inrush current applications
• Rated for 230V and 400V, adaptable to various systems
• 10 kA breaking capacity for enhanced safety and reliability
• Easy installation on DIN rails for diverse setups
• IP20 terminal protection for added safety against accidental contact
Applications
• Used in commercial lighting circuits
• Protects small motor drives
• Employed in control panels for automation systems
• Enhances circuit safety in residential installations
• Applicable in machinery where overload protection is necessary
• Protects small motor drives
• Employed in control panels for automation systems
• Enhances circuit safety in residential installations
• Applicable in machinery where overload protection is necessary
What type of systems is this suitable for?
It is suitable for various electrical systems, including residential and commercial applications.
Can it handle high inrush currents?
Yes, as a Type D MCB, it is designed for applications with high inrush currents.
What maintenance is required for optimal performance?
Regular visual inspections are recommended to ensure connections remain secure and undamaged.
Lovato MCBs
Gerelateerde Links
- Lovato ModuLo P1MB MCB 2A Curve C 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 2A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 6A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 1A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 25A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 4A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 63A Curve B 80V DC, 10 kA Breaking Capacity
- Lovato ModuLo P1MB MCB 50A Curve D 80V DC, 10 kA Breaking Capacity