- RS-stocknr.:
- 847-3153
- Fabrikantnummer:
- 278848 FAZ-B20/3
- Fabrikant:
- Eaton
5 op voorraad - levertijd is 1 werkdag(en).
Prijs Per stuk
€ 93,37
(excl. BTW)
€ 112,98
(incl. BTW)
Aantal stuks | Per stuk |
1 - 9 | € 93,37 |
10 - 14 | € 89,64 |
15 + | € 85,90 |
- RS-stocknr.:
- 847-3153
- Fabrikantnummer:
- 278848 FAZ-B20/3
- Fabrikant:
- Eaton
Eaton FAZ Series Circuit Breakers
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eatons FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
Features and Benefits
The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Eaton 3-Pole MCB, 20A Current Rating, B Curve - FAZ Series - 278848 FAZ-B20/3
Features & Benefits
• Easy to snap onto a DIN rail for quick and convenient installation
• Meets IEC 60947-2 safety standards for circuit breakers used in low-voltage electrical power distribution systems
• Protected against impact and vibration, so is suitable to use in demanding settings
• Slim mounting width per pole of 17.5mm for maximum packing efficiency in a control cabinet
• Meets IEC 60947-2 safety standards for circuit breakers used in low-voltage electrical power distribution systems
• Protected against impact and vibration, so is suitable to use in demanding settings
• Slim mounting width per pole of 17.5mm for maximum packing efficiency in a control cabinet
What does trip curve mean?
The trip curve of a circuit breaker refers to the strength of an overcurrent that the device can safely break.
Do I have to replace this MCB once it's tripped?
No, this MCB is manually re-settable, so there's no need to replace it once it's tripped.
Note
Eaton formerly known as Moeller
Kenmerk | Waarde |
---|---|
Number of Poles | 3P |
Current Rating | 20A |
Tripping Characteristics | Type B |
Rated AC Voltage | 240 → 415V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | xEffect |
Circuit Breaker Type | MCB |
Width | 85mm |
Length | 54mm |
Mounting Style | DIN Rail Mount |
Depth | 73mm |
Model Number | 278848 |
Application | Commercial, Residential |
- RS-stocknr.:
- 847-3153
- Fabrikantnummer:
- 278848 FAZ-B20/3
- Fabrikant:
- Eaton
Eaton FAZ Series Circuit Breakers
The FAZ series by Eaton offers a wide range of quality, highly reliable and safe circuit breakers. Eatons FAZ DIN rail mountable circuit breaker is designed for use in control panel applications.
Features and Benefits
The Eaton miniature circuit breaker has a current limiting design, providing short circuit interruption to reduce let-through energy, which can damage the circuit.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Rated currents up to 63A.
The toggle can be sealed in both the on and off position where required, and the trip-free design means that the breaker cannot be defeated by holding the handle in the on position.
Reliable and safe operation with six levels of thermal-magnetic over-current protection.
Red or green light indicates the contact position.
Easy installation.
Suitable for supplementary protection.
Eaton 3-Pole MCB, 20A Current Rating, B Curve - FAZ Series - 278848 FAZ-B20/3
Features & Benefits
• Easy to snap onto a DIN rail for quick and convenient installation
• Meets IEC 60947-2 safety standards for circuit breakers used in low-voltage electrical power distribution systems
• Protected against impact and vibration, so is suitable to use in demanding settings
• Slim mounting width per pole of 17.5mm for maximum packing efficiency in a control cabinet
• Meets IEC 60947-2 safety standards for circuit breakers used in low-voltage electrical power distribution systems
• Protected against impact and vibration, so is suitable to use in demanding settings
• Slim mounting width per pole of 17.5mm for maximum packing efficiency in a control cabinet
What does trip curve mean?
The trip curve of a circuit breaker refers to the strength of an overcurrent that the device can safely break.
Do I have to replace this MCB once it's tripped?
No, this MCB is manually re-settable, so there's no need to replace it once it's tripped.
Note
Eaton formerly known as Moeller
Kenmerk | Waarde |
---|---|
Number of Poles | 3P |
Current Rating | 20A |
Tripping Characteristics | Type B |
Rated AC Voltage | 240 → 415V |
Breaking Capacity at Maximum Voltage Rating | 10 kA |
Range | xEffect |
Circuit Breaker Type | MCB |
Width | 85mm |
Length | 54mm |
Mounting Style | DIN Rail Mount |
Depth | 73mm |
Model Number | 278848 |
Application | Commercial, Residential |