Eaton xEffect FAZ MCB, 1P, 1A Curve C, 240V AC, 48V DC, 10 kA Breaking Capacity
- RS-stocknr.:
- 922-6995
- Fabrikantnummer:
- 278546 FAZ-C1/1
- Fabrikant:
- Eaton
Subtotaal (1 eenheid)*
€ 28,11
(excl. BTW)
€ 34,01
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- Plus verzending 49 stuk(s) vanaf 05 januari 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 28,11 |
*prijsindicatie
- RS-stocknr.:
- 922-6995
- Fabrikantnummer:
- 278546 FAZ-C1/1
- Fabrikant:
- Eaton
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Eaton | |
| Number of Poles | 1 | |
| Current Rating | 1A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 240V | |
| Rated DC Voltage | 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | xEffect | |
| Series | FAZ | |
| Circuit Breaker Type | MCB | |
| Width | 17.7mm | |
| Length | 80mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 80mm | |
| Break Time | Instantaneous | |
| Tripping Mechanism | Thermal-Magnetic | |
| Reset Actuator Type | Toggle Switch | |
| Application | Commercial, Industrial | |
| Terminal Contact Type | Screw | |
| Alles selecteren | ||
|---|---|---|
Merk Eaton | ||
Number of Poles 1 | ||
Current Rating 1A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 240V | ||
Rated DC Voltage 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range xEffect | ||
Series FAZ | ||
Circuit Breaker Type MCB | ||
Width 17.7mm | ||
Length 80mm | ||
Mounting Style DIN Rail Mount | ||
Depth 80mm | ||
Break Time Instantaneous | ||
Tripping Mechanism Thermal-Magnetic | ||
Reset Actuator Type Toggle Switch | ||
Application Commercial, Industrial | ||
Terminal Contact Type Screw | ||
Eaton FAZ Series MCB, 1 Pole, 1A Current Rating - 278546 FAZ-C1/1
This miniature circuit breaker (MCB) serves as an essential component for electrical safety in commercial and industrial environments. The 1P MCB features a current rating of 1A and a robust design measuring 17.7 mm in width and 80 mm in length. It provides protection with a breaking capacity of 10kA, ensuring reliability and efficiency in various applications.
Features & Benefits
• Supports instantaneous tripping for rapid response
• Type C circuit breaker suitable for standard load requirements
• Thermal-magnetic mechanism enhances protection against overloads
• Screw terminal type ensures secure electrical connections
• DIN rail mounting offers easy installation in switchgear
• Operates effectively across a wide temperature range from -40°C to 75°C
• Type C circuit breaker suitable for standard load requirements
• Thermal-magnetic mechanism enhances protection against overloads
• Screw terminal type ensures secure electrical connections
• DIN rail mounting offers easy installation in switchgear
• Operates effectively across a wide temperature range from -40°C to 75°C
Applications
• Used for protecting electrical circuits in commercial installations
• Suitable for industrial machinery and equipment safeguards
• Ideal for requiring instantaneous overload protection
• Utilised in switchgear setups for enhanced operational safety
• Suitable for industrial machinery and equipment safeguards
• Ideal for requiring instantaneous overload protection
• Utilised in switchgear setups for enhanced operational safety
What are the benefits of using a Type C circuit breaker for my applications?
A Type C circuit breaker is designed to trip at higher fault currents, making it practical for circuits with inductive loads like motors. It offers protection against overloads while allowing temporary inrush currents, ensuring operational efficiency and safety.
How does the thermal-magnetic mechanism contribute to circuit protection?
This mechanism combines thermal and magnetic tripping functions. The thermal element reacts to prolonged overloads, while the magnetic component responds to short-circuit conditions, ensuring comprehensive protection against diverse electrical faults.
What is the operational voltage range for this circuit breaker?
The circuit breaker is rated for an operational AC voltage of 240 V and can handle up to 415 V, making it versatile for various electrical systems while adhering to IEC standards.
Note
Eaton formerly known as Moeller
Gerelateerde Links
- Eaton xEffect FAZ MCB 1A Curve C 60V DC, 15 kA Breaking Capacity
- Eaton xEffect FAZ MCB 1A Curve C 60V DC, 7.5 kA Breaking Capacity
- Eaton xEffect MCB 1A Curve D 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 1A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect MCB 1A Curve C 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 1A Curve B 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 1A Curve K 48V DC, 10 kA Breaking Capacity
- Eaton xEffect FAZ MCB 1A Curve B 60V DC, 15 kA Breaking Capacity