Infineon XMC1402F064X0200AAXUMA1, 32 bit ARM Cortex M0, XMC1400 Microcontroller, 32 MHz, 200kB FLASH, 64-Pin LQFP
- RS-stocknr.:
- 218-4426
- Fabrikantnummer:
- XMC1402F064X0200AAXUMA1
- Fabrikant:
- Infineon
Bulkkorting beschikbaar
Subtotaal (1 verpakking van 5 eenheden)*
€ 16,30
(excl. BTW)
€ 19,70
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 24 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk | Per verpakking* |
|---|---|---|
| 5 - 5 | € 3,26 | € 16,30 |
| 10 - 95 | € 2,992 | € 14,96 |
| 100 - 245 | € 2,764 | € 13,82 |
| 250 - 495 | € 2,564 | € 12,82 |
| 500 + | € 2,492 | € 12,46 |
*prijsindicatie
- RS-stocknr.:
- 218-4426
- Fabrikantnummer:
- XMC1402F064X0200AAXUMA1
- Fabrikant:
- Infineon
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Infineon | |
| Series | XMC1400 | |
| Product Type | Microcontroller | |
| Package Type | LQFP | |
| Mount Type | Surface | |
| Pin Count | 64 | |
| Device Core | ARM Cortex M0 | |
| Data Bus Width | 32bit | |
| Program Memory Size | 200kB | |
| Maximum Clock Frequency | 32MHz | |
| RAM Size | 16kB | |
| Maximum Supply Voltage | 5.5V | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 105°C | |
| Length | 10mm | |
| Analogue Comparators | 4 | |
| Standards/Approvals | No | |
| Number of Programmable I/Os | 48 | |
| Width | 10 mm | |
| Minimum Supply Voltage | 1.8V | |
| ADCs | 12 x 12 Bit | |
| Program Memory Type | FLASH | |
| Automotive Standard | No | |
| Number of Timers | 16 | |
| Alles selecteren | ||
|---|---|---|
Merk Infineon | ||
Series XMC1400 | ||
Product Type Microcontroller | ||
Package Type LQFP | ||
Mount Type Surface | ||
Pin Count 64 | ||
Device Core ARM Cortex M0 | ||
Data Bus Width 32bit | ||
Program Memory Size 200kB | ||
Maximum Clock Frequency 32MHz | ||
RAM Size 16kB | ||
Maximum Supply Voltage 5.5V | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 105°C | ||
Length 10mm | ||
Analogue Comparators 4 | ||
Standards/Approvals No | ||
Number of Programmable I/Os 48 | ||
Width 10 mm | ||
Minimum Supply Voltage 1.8V | ||
ADCs 12 x 12 Bit | ||
Program Memory Type FLASH | ||
Automotive Standard No | ||
Number of Timers 16 | ||
Infineon Microcontroller, 64 Pin Count, 200 kB Program Memory size - XMC1402F064X0200AAXUMA1
This sensor is a condensation detector designed for surface mounting, measuring 83mm in height and 60mm in length. Ideal for monitoring condensation in environments with chilled ceilings and HVAC systems, it operates with a supply voltage of 24V AC/DC. Weighing only 0.126kg, this reliable device features an IP40 rating, making it suitable for various industrial applications.
Features & Benefits
• Accurately monitors humidity levels near the dew point
• Prevents condensation damage on chilled ceilings
• Functions as a condensation switch for HVAC systems
• Built with a flame-retardant thermoplastic housing
• Supports mounting on surfaces or via tensioning straps
• Quick response time stabilises operations under rising humidity
Applications
• Monitor condensation in buildings with HVAC systems
• Used for chilled ceiling to prevent moisture build-up
• Suitable for detection at critical points in air conditioning
• Effective in ventilation systems to mitigate condensation risk
• Ideal for mounting on pipes with diameters from 10mm to 100mm
How does the condensation detection technology function in this device?
The device operates by recording relative humidity close to the dew point. It activates the relay before reaching this point, allowing immediate adjustments to the cooling processes to prevent condensation.
What precautions should be taken when installing the sensor?
It is essential to mount the sensor in the coldest area of the surface it protects. Additionally, applying a thin layer of thermal conductive paste on the mounting surface enhances accuracy and performance.
What is the expected response time for humidity changes?
The sensor displays a maximum response time of 3 minutes when detecting humidity variations from 80% to 99% relative humidity. This quick action helps maintain optimal conditions in sensitive environments.
Gerelateerde Links
- Infineon XMC1400 Microcontroller 200 kB Flash, 64-Pin LQFP
- STMicroelectronics STM32F0 Microcontroller 128 kB Flash, 64-Pin LQFP
- STMicroelectronics ARM Cortex M0+ Microcontroller 16 KB Flash, 32-Pin LQFP
- STMicroelectronics ARM Cortex M0+ Microcontroller 16 KB Flash, 48-Pin LQFP
- STMicroelectronics ARM Cortex M0+ Microcontroller 32 KB Flash, 48-Pin LQFP-48
- STMicroelectronics STM32F0 Microcontroller 64 kB Flash, 64-Pin LQFP
- NXP Kinetis Microcontroller 64 KB Flash, 64-Pin LQFP
- STMicroelectronics STM32F0 Microcontroller 128 kB Flash, 48-Pin LQFP