Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Pilz | |
| Product Type | Monitoring Relay | |
| Function | Phase Sequence | |
| Electrical Phase | 3 | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Switching Voltage | 240V | |
| Power Consumption | 15VA | |
| Terminal Type | Screw | |
| IP Rating | IP20, IP40, IP54 | |
| Minimum Operating Temperature | -15°C | |
| Supply AC Voltage | 500V ac | |
| Contact Current | 6A | |
| Monitoring Voltage Range | 400 to 500 V | |
| Maximum Operating Temperature | 55°C | |
| Series | S1PN | |
| Height | 87mm | |
| Width | 22.5mm | |
| Standards/Approvals | No | |
| Alles selecteren | ||
|---|---|---|
Merk Pilz | ||
Product Type Monitoring Relay | ||
Function Phase Sequence | ||
Electrical Phase 3 | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Switching Voltage 240V | ||
Power Consumption 15VA | ||
Terminal Type Screw | ||
IP Rating IP20, IP40, IP54 | ||
Minimum Operating Temperature -15°C | ||
Supply AC Voltage 500V ac | ||
Contact Current 6A | ||
Monitoring Voltage Range 400 to 500 V | ||
Maximum Operating Temperature 55°C | ||
Series S1PN | ||
Height 87mm | ||
Width 22.5mm | ||
Standards/Approvals No | ||
Vrijgesteld
- Land van herkomst:
- FR
The Pliz Phase Sequence Monitoring Relay detects the time sequence of the individual phases in a three phase supply. In a clockwise phase sequence, contacts 11-12 and 21-22 are open, contacts 11-14 and 21-24 are closed. In an anti-clockwise phase sequence, contacts 11-14 and 21-24 are open, contacts 11-12 and 21-22 are closed.
Measuring voltage up to 690 VAC
Phase sequence monitoring
Phase failure monitoring
Fuse monitoring LEDs
Extensive voltage range
Gerelateerde Links
- Pilz Monitoring Relay 400 to 500 V Monitor Range DIN Rail, 500V ac
- Tele Monitoring Relay 400 V ac Monitor Range DIN Rail, 400V ac
- GIC Monitoring Relay 145 to 500 V Monitor Range DIN, 500V
- Tele Monitoring Relay 230/400 V ac Monitor Range DIN Rail, 250V ac
- GIC Monitoring Relay 145 to 500 V Monitor Range DIN, 500V
- Omron Monitoring Relay 200/400 V ac Monitor Range DIN Rail 400 V ac 30 V ac
- Tele Monitoring Relay 160 to 240 V Monitor Range DIN Rail 400 V ac
- Siemens Monitoring Relay 90/400 V ac Monitor Range Snap-On 90 V ac