Omron Monitoring Relay, SPDT, DIN Rail, Monitoring: 0 °C to 999 °C
- RS-stocknr.:
- 111-3131
- Fabrikantnummer:
- K8DT-TH2CA
- Fabrikant:
- Omron
Subtotaal (1 eenheid)*
€ 165,74
(excl. BTW)
€ 200,55
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
Op voorraad
- Plus verzending 5 stuk(s) vanaf 10 juni 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 165,74 |
*prijsindicatie
- RS-stocknr.:
- 111-3131
- Fabrikantnummer:
- K8DT-TH2CA
- Fabrikant:
- Omron
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Omron | |
| Product Type | Monitoring Relay | |
| Sub Type | Thermocouple | |
| Contact Configuration | SPDT | |
| Mount Type | DIN Rail | |
| Terminal Type | Push-in | |
| IP Rating | IP20 | |
| Minimum Temperature Monitoring | 0°C | |
| Contact Current | 10A | |
| Minimum Operating Temperature | -20°C | |
| Maximum Temperature Monitoring | 999°C | |
| Maximum Operating Temperature | 60°C | |
| Standards/Approvals | RoHS, UL 61010-1, EN 61326-1, EN 61010-1 | |
| Series | K8DT-TH | |
| Width | 17.5mm | |
| Height | 90mm | |
| Length | 90mm | |
| Alles selecteren | ||
|---|---|---|
Merk Omron | ||
Product Type Monitoring Relay | ||
Sub Type Thermocouple | ||
Contact Configuration SPDT | ||
Mount Type DIN Rail | ||
Terminal Type Push-in | ||
IP Rating IP20 | ||
Minimum Temperature Monitoring 0°C | ||
Contact Current 10A | ||
Minimum Operating Temperature -20°C | ||
Maximum Temperature Monitoring 999°C | ||
Maximum Operating Temperature 60°C | ||
Standards/Approvals RoHS, UL 61010-1, EN 61326-1, EN 61010-1 | ||
Series K8DT-TH | ||
Width 17.5mm | ||
Height 90mm | ||
Length 90mm | ||
- Land van herkomst:
- CN
Omron K8DT-TH Series Monitoring Relay, 10A Contact Current, 100 to 240V Supply AC Voltage - K8DT-TH2CA
This monitoring relay provides thermocouple-based temperature supervision for industrial control environments. Designed for DIN-rail mounting, it accepts thermocouple inputs and monitors temperatures across a wide span, supplying an SPDT switching output to control circuits. The unit operates from a universal AC supply and is suitable for panel installations where compactness and discrete switching are required.
Features and Benefits:
• 100–240V AC supply enables flexible global power integration
• SPDT contact rated 10A supports direct load switching
• Push-in terminals permit fast, tool-free wiring
• Monitors up to 999°C for extreme-temperature applications
• Operating range −20°C to 60°C allows varied ambient use
• SPDT contact rated 10A supports direct load switching
• Push-in terminals permit fast, tool-free wiring
• Monitors up to 999°C for extreme-temperature applications
• Operating range −20°C to 60°C allows varied ambient use
Applications
• Suitable for process furnaces requiring high-temperature limits
• Ideal for thermal safety interlocks on industrial equipment
• Used with controllers in manufacturing temperature monitoring
• Can be used for oven and kiln over-temperature protection
• Ideal for thermal safety interlocks on industrial equipment
• Used with controllers in manufacturing temperature monitoring
• Can be used for oven and kiln over-temperature protection
What mounting method does it use for panel integration?
It clips onto standard DIN rail for secure, space-efficient installation and straightforward removal during maintenance.
What electrical safety and electromagnetic standards apply?
It conforms to recognised standards covering electrical measurement and EMC to ensure predictable operation in industrial installations.
How narrow is the unit for dense control panels?
The relay occupies a slim profile of 17.5mm, permitting high-density mounting on DIN rails.
What Terminal connection style is provided for field wiring?
Push-in terminations accept conductors without screws, reducing wiring time and improving connection consistency.
Which environmental protection rating does the enclosure meet?
The housing provides IP20 ingress protection appropriate for guarded electrical compartments.
Push-In Plus Terminals
Push-In Plus Terminal blocks on all K8DT relays reduce the time and work involved in wiring. The Push-In Plus Terminals allow solid and stranded wires with pin Terminals or ferrules to be inserted without the need for tools.
Standards
EN61010-1, EN 61326-1, UL 61010-1 IP 20 Terminals
Gerelateerde Links
- Omron Monitoring Relay DIN Rail, Monitoring: 0 °C to 999 °C 0 V ac
- Omron Monitoring Relay DIN Rail 24 V 24V
- Omron Monitoring Relay DIN Rail, Monitoring: 0 °C to 999 °C 0 V ac
- Omron Monitoring Relay DIN Rail 0 V ac 0 V ac
- Omron Monitoring Relay DIN Rail 24.4 to 26.4 V ac 24.4/26.4 V ac
- Omron Monitoring Relay SPDT Monitoring: 0 °C to 999 °C, 24 V dc 100/240 V ac
- Omron Monitoring Relay DIN Rail 24 V dc 24 V ac, 100/240 V ac
- Omron Monitoring Relay 0 V ac Monitor Range DIN Rail, 0V ac