Dold Monitoring Relay, 3 Phase, 0.7 to 1.3 UN Monitor Range, DPDT, DIN Rail 80 to 230 V dc
- RS-stocknr.:
- 240-8967
- Fabrikantnummer:
- BD9080.12 3AC400V UH=AC230V
- Fabrikant:
- Dold
Subtotaal (1 eenheid)*
€ 401,18
(excl. BTW)
€ 485,43
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 15 stuk(s) klaar voor verzending
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 401,18 |
*prijsindicatie
- RS-stocknr.:
- 240-8967
- Fabrikantnummer:
- BD9080.12 3AC400V UH=AC230V
- Fabrikant:
- Dold
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Dold | |
| Product Type | Monitoring Relay | |
| Electrical Phase | 3 | |
| Function | Undervoltage Monitoring, Phase Failure, Asymmetry, Phase Sequence | |
| Contact Configuration | DPDT | |
| Mount Type | DIN Rail | |
| Power Consumption | 2.4VA | |
| Switching Voltage | 230V ac | |
| Terminal Type | Screw Terminal | |
| IP Rating | IP20, IP40 | |
| Contact Current | 6A | |
| Monitoring Voltage Range | 0.7 to 1.3 UN | |
| Supply DC Voltage | 80 to 230 V dc | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 60°C | |
| Height | 74mm | |
| Series | BD 9080 | |
| Width | 45mm | |
| Standards/Approvals | IEC/EN 61 000-4-4, IEC/EN 60 715, IEC/EN 61 000-4-6, IEC/EN 60 068-1, IEC/EN 61 000-4-3, IEC/EN 60 068-2-6, IEC/EN 61 000-4-5, UL Subject 94, IEC/EN 61 000-4-2, IEC/EN 60255-1, IEC/EN 60 529, IEC/EN 61 373, IEC/EN 60 947-5-1, DIN EN 50155, IEC 60 664-1, DIN 46 228-1/-2/-3/-4, EN 55 011 | |
| Length | 133mm | |
| Alles selecteren | ||
|---|---|---|
Merk Dold | ||
Product Type Monitoring Relay | ||
Electrical Phase 3 | ||
Function Undervoltage Monitoring, Phase Failure, Asymmetry, Phase Sequence | ||
Contact Configuration DPDT | ||
Mount Type DIN Rail | ||
Power Consumption 2.4VA | ||
Switching Voltage 230V ac | ||
Terminal Type Screw Terminal | ||
IP Rating IP20, IP40 | ||
Contact Current 6A | ||
Monitoring Voltage Range 0.7 to 1.3 UN | ||
Supply DC Voltage 80 to 230 V dc | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 60°C | ||
Height 74mm | ||
Series BD 9080 | ||
Width 45mm | ||
Standards/Approvals IEC/EN 61 000-4-4, IEC/EN 60 715, IEC/EN 61 000-4-6, IEC/EN 60 068-1, IEC/EN 61 000-4-3, IEC/EN 60 068-2-6, IEC/EN 61 000-4-5, UL Subject 94, IEC/EN 61 000-4-2, IEC/EN 60255-1, IEC/EN 60 529, IEC/EN 61 373, IEC/EN 60 947-5-1, DIN EN 50155, IEC 60 664-1, DIN 46 228-1/-2/-3/-4, EN 55 011 | ||
Length 133mm | ||
- Land van herkomst:
- DE


Phase monitor, BD9080
Phase Sequence/Failure Relays
Gerelateerde Links
- Dold Monitoring Relay 0.7 to 1.1 UN Monitor Range DIN Rail
- Dold Monitoring Relay DIN Rail 12 V dc, 230 V ac
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range DIN Rail
- Dold Monitoring Relay DIN Rail, 230 V ac 24 V dc
- Dold Monitoring Relay 0.8 to 1.1 UN Monitor Range 400 V ac
- Dold Monitoring Relay 3 Phase DIN Rail
- Dold Monitoring Relay 1 Phase DIN Rail
- Dold Monitoring Relay SPDT 100mA to 12A 230 V ac