Fluke FTPL-1 Fused Test Probe Lead, CAT III, CAT IV, 10A

Subtotaal (1 eenheid)*

€ 174,00

(excl. BTW)

€ 210,54

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending
  • 33 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 174,00

*prijsindicatie

RS-stocknr.:
880-1397
Artikelnummer Distrelec:
176-00-063
Fabrikantnummer:
FTPL-1
Fabrikant:
Fluke
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke

Lead Type

Test Probe Lead

Product Type

Multimeter Leads

Current

10A

Connector Type

Straight, Right Angle

Fused

Yes

Lead Length

1.5m

Safety Category Voltage

1000, 600V

Minimum Operating Temperature

-20°C

Safety Category Level

CAT III, CAT IV

Maximum Operating Temperature

50°C

Standards/Approvals

No

Vrijgesteld

Land van herkomst:
TW

Fluke Multimeter Leads, 1.5m Lead Length, 10A Current - FTPL-1


This multimeter leads set provides fused test probes and silicone-insulated leads for safe voltage and continuity measurements in industrial environments. Designed for use where category-rated protection and clear live-voltage indication are required, the set pairs modular probes with a combination of straight and right-angle connectors and removable tip accessories for targeted probing.

Features & Benefits


• Built-in fuses rated 11A with 20kA interrupt limit for added protection
• Probes indicate live voltage even when a fuse has blown to avoid false zero readings
• 2mm threaded tips with removable 4mm spring contacts for flexible contact options
• Right-angle on one end and straight connector on the other for access in tight spaces
• Silicone-insulated 1.5m leads resist extremes from -20°C to 50°C for field use

**Applications**


• Suitable for on-site fault finding in electrical distribution panels
• Ideal for measurements on control systems in automation environments
• Used for component testing in electronics assembly and repair
• Can be used for diagnostic work on mechanical plant with limited probe clearance

How can I verify the fused probe before taking current measurements?


Check probe continuity with the meter

a fused probe must show continuity to enable current mode since the fuse disables current measurement when open.

Are the probe tips adaptable for probing closely spaced contacts?


Yes, the threaded 2mm tips accept removable insulated caps and 4mm spring contacts to reduce exposed metal and adapt to tight pitches.

What happens to voltage indication if a fuse opens during a live test?


The probes still permit an approximate voltage reading through the meter input impedance, but results vary by meter and should be confirmed by a continuity check.

What electrical categories and voltages do these leads support?


They are rated for CAT III at 1000V and CAT IV at 600V and for use up to a 10A continuous current rating.