Fluke 3000 FC 3000 FC Digital Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Subtotaal (1 eenheid)*
€ 454,00
(excl. BTW)
€ 549,34
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 90,00
- 3 resterend, klaar voor verzending
- 32 stuk(s) klaar voor verzending vanaf een andere locatie
- Plus verzending 3 stuk(s) vanaf 15 mei 2026
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 454,00 |
*prijsindicatie
- RS-stocknr.:
- 811-1316
- Artikelnummer Distrelec:
- 110-83-815
- Fabrikantnummer:
- FLK-3000 FC
- Fabrikant:
- Fluke
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Fluke | |
| Multimeter Type | Digital | |
| Product Type | Multimeter | |
| Model Number | 3000 FC | |
| Resistance Resolution | 100mΩ | |
| Display Type | Digital | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum DC Current Measurement | 400mA dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum Resistance Measurement | 50mΩ | |
| True RMS | Yes | |
| AC Voltage Accuracy | ± 1 % + 3 | |
| DC Current Accuracy | ±0.5 % | |
| AC Current Accuracy | ±1.5 % | |
| DC Voltage Accuracy | ±0.09 % | |
| DC Voltage Resolution | 0.1 mV dc | |
| DC Current Resolution | 0.01mA dc | |
| AC Voltage Resolution | 0.1mV ac | |
| AC Current Resolution | 0.01mA ac | |
| Maximum Frequency | 99.99kHz | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 250h | |
| Length | 207mm | |
| Height | 47.5mm | |
| Series | 3000 FC | |
| Width | 93mm | |
| Standards/Approvals | No | |
| Weight | 340g | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA Alkaline | |
| Safety Category Voltage | 1000V | |
| Alles selecteren | ||
|---|---|---|
Merk Fluke | ||
Multimeter Type Digital | ||
Product Type Multimeter | ||
Model Number 3000 FC | ||
Resistance Resolution 100mΩ | ||
Display Type Digital | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum DC Current Measurement 400mA dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum Resistance Measurement 50mΩ | ||
True RMS Yes | ||
AC Voltage Accuracy ± 1 % + 3 | ||
DC Current Accuracy ±0.5 % | ||
AC Current Accuracy ±1.5 % | ||
DC Voltage Accuracy ±0.09 % | ||
DC Voltage Resolution 0.1 mV dc | ||
DC Current Resolution 0.01mA dc | ||
AC Voltage Resolution 0.1mV ac | ||
AC Current Resolution 0.01mA ac | ||
Maximum Frequency 99.99kHz | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Battery Life 250h | ||
Length 207mm | ||
Height 47.5mm | ||
Series 3000 FC | ||
Width 93mm | ||
Standards/Approvals No | ||
Weight 340g | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA Alkaline | ||
Safety Category Voltage 1000V | ||
Vrijgesteld
- Land van herkomst:
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
**Applications**
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Gerelateerde Links
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS 400 mA dc, 1 kV ac - UKAS Calibrated
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS 400 mA dc, 1 kV ac - RSCAL Calibrated
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac - UKAS Calibrated
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac - RSCAL Calibrated
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1 kV ac
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1 kV ac - UKAS Calibrated
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1 kV ac - RSCAL Calibrated
