Endress+Hauser CPS91E-AA7BHH2 Glass pH Conductivity Sensor, 0 to 14 pH
- RS-stocknr.:
- 287-1699
- Fabrikantnummer:
- CPS91E-AA7BHH2
- Fabrikant:
- Endress+Hauser
Subtotaal (1 eenheid)*
€ 478,03
(excl. BTW)
€ 578,42
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Op voorraad
- 3 stuk(s) klaar voor verzending
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 478,03 |
*prijsindicatie
- RS-stocknr.:
- 287-1699
- Fabrikantnummer:
- CPS91E-AA7BHH2
- Fabrikant:
- Endress+Hauser
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | Endress+Hauser | |
| Product Type | Conductivity Sensor | |
| Measurement Range | 0 to 14 pH | |
| Electrode Type | pH | |
| Probe Type | Glass | |
| Standards/Approvals | No | |
| Alles selecteren | ||
|---|---|---|
Merk Endress+Hauser | ||
Product Type Conductivity Sensor | ||
Measurement Range 0 to 14 pH | ||
Electrode Type pH | ||
Probe Type Glass | ||
Standards/Approvals No | ||
- Land van herkomst:
- DE
The ENDRESS+HAUSER Memosens CPS91E digital pH sensor is designed for measuring pH in chemicals, paper, and paint applications. With its Memosens 2.0 digital technology, this sensor offers enhanced data storage for predictive maintenance and IIoT capabilities. It features an open aperture that prevents fouling and ensures reliable measurement in fibrous media or media with a high content of suspended solids. The CPS91E is completely resistant to moisture and can be pre-calibrated in the lab, simplifying operation and improving process integrity.
Open aperture design prevents fouling and ensures reliable measurement in heavily soiled media
Not affected by fluctuations in pressure and temperature for consistent accuracy
Memosens 2.0 technology offers extended storage of calibration and process data for better trend identification and predictive maintenance
Non-contact, inductive signal transmission eliminates disturbances caused by moisture or corrosion
Lab calibration and quick sensor exchange maximize process uptime and reduce operating costs
Gerelateerde Links
- Endress+Hauser CPS91E-BA7BHH2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS91E-AA7BTH2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS61E-BA6NTP2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS71E-AA7HTP2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPF81E-UR5LAD2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS71E-BA7BTB2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS71E-BA7BTC2 Glass pH Conductivity Sensor, 0 to 14 pH
- Endress+Hauser CPS41E-AA7BSB2 Glass pH Conductivity Sensor, 0 to 14 pH