Fluke 1775 Power Quality Analyser, 3-Phase, 2000 A Max, 1000V dc

Subtotaal (1 eenheid)*

€ 9.880,00

(excl. BTW)

€ 11.954,80

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 3 stuk(s) klaar voor verzending
  • 4 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 9.880,00

*prijsindicatie

RS-stocknr.:
232-0533
Artikelnummer Distrelec:
302-40-452
Fabrikantnummer:
FLUKE-1775
Fabrikant:
Fluke
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Fluke

Maximum Current Measurement

2000A

Product Type

Power Quality Analyser

Maximum Power Measurement

1500mW

Voltage Accuracy

±0.1 %

Number of Phases

3

Display Type

Touch Screen

Maximum Voltage Measurement

1000V dc

Measurement Type

Current, Voltage, Frequency

Measurement Standards

IEC 61010-2-30

Interface Type

Ethernet, USB

Minimum Operating Temperature

-10°C

Memory Size

8GB

Maximum Operating Temperature

50°C

Power Source

Battery

Battery Type

Lithium-ion

Standards/Approvals

IEEE 1459, IEC 61000-4-7, IEC 61000-4-15 Class F1, IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI

Height

6.2cm

Weight

2.1kg

Width

19cm

Length

280.00mm

Model Number

1775

Battery Life

1.5h

Maximum Frequency

69Hz

Minimum Frequency

42.5Hz

Land van herkomst:
RO

Fluke Power Quality Analyser, 1000V Maximum Voltage Measurement, 2000A Maximum Current Measurement - FLUKE-1775


This power quality analyser is a handheld instrument for capturing and logging electrical power and quality parameters in three-phase systems. It records voltage, current and frequency behaviour while detecting fast transients, dips, swells and harmonics to support on-site troubleshooting and energy studies. The unit operates from its internal lithium-ion power source or directly from the measured circuit and presents data on a colour touch screen for immediate field assessment.

Features & Benefits


• 1MHz transient sampling captures high-speed disturbances for mitigation
• 1000V rms voltage measurement enables service-entrance testing
• 2000A clamp-on current input supports large conductor measurement
• ±0.1% voltage accuracy provides precise diagnostic readings
• 8GB internal memory stores long-duration energy logging sessions
• IEC 61000-4-30 Class A measurement ensures standardised PQ data

**Applications**


• Suitable for industrial power quality troubleshooting at distribution panels
• Ideal for energy loss calculations and financial loss estimation
• Used for harmonic surveys to compare against IEEE519 limits
• Can be used for transient discovery to prevent equipment failure
• Used with clamp and Rogowski probes for large-motor load studies

How long can it run away from the mains before recharging?


On its internal lithium-ion battery it provides about 75 minutes of on-battery operation for review and portable checks.

Which interfaces allow data transfer to analysis software?


Data can be downloaded via USB-C, USB-A, wired Ethernet, WiFi or cellular connectivity for use with supplied analysis software.

How does timing synchronisation work for multi-site correlation?


The instrument offers internal real-time clock accuracy, NTP synchronisation and optional GPS antenna input for sub-millisecond time alignment.

What range of frequencies and harmonics does it log?


It supports mains frequencies from 42.5Hz to 69Hz and records up to 100 integer harmonics Plus supraharmonics to 30kHz depending on configuration.