onsemi 5 PWM Controller, 65 kHz 28 V 7-Pin, SOIC
- RS-stocknr.:
- 178-4347
- Fabrikantnummer:
- NCP12400CBAAB0DR2G
- Fabrikant:
- onsemi
Momenteel niet beschikbaar
We weten niet of dit item nog op voorraad komt, RS is van plan dit binnenkort uit ons assortiment te halen.
- RS-stocknr.:
- 178-4347
- Fabrikantnummer:
- NCP12400CBAAB0DR2G
- Fabrikant:
- onsemi
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | onsemi | |
| Product Type | PWM Controller | |
| Maximum Switching Frequency | 65kHz | |
| Output Voltage | 14 V | |
| Output Current | 500mA | |
| Zero Power Detection | No | |
| Number of Outputs | 5 | |
| Mount Type | Surface | |
| Minimum Supply Voltage | -0.3V | |
| Package Type | SOIC | |
| Maximum Supply Voltage | 28V | |
| Topology | Flyback | |
| Pin Count | 7 | |
| Minimum Operating Temperature | -40°C | |
| Maximum Duty Cycle | 85% | |
| PWM Controller Type | Current Mode | |
| Maximum Operating Temperature | 150°C | |
| Series | NCP | |
| Standards/Approvals | No | |
| Width | 4 mm | |
| Length | 5mm | |
| Height | 1.5mm | |
| Automotive Standard | No | |
| Alles selecteren | ||
|---|---|---|
Merk onsemi | ||
Product Type PWM Controller | ||
Maximum Switching Frequency 65kHz | ||
Output Voltage 14 V | ||
Output Current 500mA | ||
Zero Power Detection No | ||
Number of Outputs 5 | ||
Mount Type Surface | ||
Minimum Supply Voltage -0.3V | ||
Package Type SOIC | ||
Maximum Supply Voltage 28V | ||
Topology Flyback | ||
Pin Count 7 | ||
Minimum Operating Temperature -40°C | ||
Maximum Duty Cycle 85% | ||
PWM Controller Type Current Mode | ||
Maximum Operating Temperature 150°C | ||
Series NCP | ||
Standards/Approvals No | ||
Width 4 mm | ||
Length 5mm | ||
Height 1.5mm | ||
Automotive Standard No | ||
- Land van herkomst:
- PH
The NCP12400 is a new fixed−frequency current−mode controller featuring the Dynamic Self−Supply. This function greatly simplifies the design of the auxiliary supply and the VCC capacitor by activating the internal startup current source to supply the controller during start−up, transients, latch, stand−by etc. This device contains a special HV detector which detects the application unplug from the ac input line and triggers the X2 discharge current. This HV structure allows the brown−out detection as well. It features a timer−based fault detection that ensures the detection of overload and an adjustable compensation to help keep the maximum power independent of the input voltage.
Reduces Overall System Cost and Complexity
Ensures Skip Mode Operation Outside Audible Range
Average Efficiency Meets CoC Tier 2 Compliance
Configurable Protection Tailored for Application Needs