ABB Residual Current Circuit Breaker with Overload Protection, 16 A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type
- RS-stocknr.:
- 201-6959
- Fabrikantnummer:
- 2CSR275180R1165 DS201 M B16 A30
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 160,59
(excl. BTW)
€ 194,31
(incl. BTW)
Informatie over voorraden is momenteel niet toegankelijk - Controleer het later nog eens opnieuw
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 160,59 |
*prijsindicatie
- RS-stocknr.:
- 201-6959
- Fabrikantnummer:
- 2CSR275180R1165 DS201 M B16 A30
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Current Rating | 16 A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Number of Poles | 2 | |
| Range | System Pro M Compact | |
| Series | DS201 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 240 V ac | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | Type A | |
| Depth | 69mm | |
| Height | 85mm | |
| Width | 35 mm | |
| Standards/Approvals | CCC, CSA, UL | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Thermal Magnetic | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Current Rating 16 A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Number of Poles 2 | ||
Range System Pro M Compact | ||
Series DS201 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Rated AC Voltage 240 V ac | ||
Terminal Type Screw | ||
Earth Leakage Protection Type Type A | ||
Depth 69mm | ||
Height 85mm | ||
Width 35 mm | ||
Standards/Approvals CCC, CSA, UL | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Thermal Magnetic | ||
ABB RCBO, 230V Rated Voltage, 10kA Rated Short-Circuit Capacity - DS201 Series - 2CSR275180R1165 DS201 M B16 A30
Looking for a complete solution to protect your single-phase electrical networks? This 2-pole RCBO from ABB immediately interrupts power supplies to help prevent damage caused by overloads and short circuits. It also safeguards against earth fault currents for improved safety. You can easily identify earth problems, thanks to the blue flag status indicator. The small unit has dimensions of 69 (L) x 35 (W) x 85mm (D), so takes up little space on crowded distribution boards. A robust plastic housing with an IP40 rating is on hand to protect against damage caused by tools and wires greater than 1mm.
Features & Benefits
• Wide operating temperature range between -25°C and +55°C for use in demanding conditions
• Mechanical endurance of 20,000 cycles for reliable performance
• Toggle switch for easy resetting
Applications
• Automated manufacturing processes
• Industrial pumps
• Electrical networks
• Computer rooms
What's the current rating of this RCBO?
It has a current rating of 16A, so can handle heavy-duty applications.
What are the connection sizes and specifications of this RCBO?
This RCBO has failsafe bi-directional cylinder-lift screw terminals. It has a connecting capacity for 10/10mm² busbar cables, 16mm² flexible cables and 25mm² stranded cables, so you can set it up according to your system's needs.
Gerelateerde Links
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole Type
- ABB Residual Current Circuit Breaker with Overload Protection 2-Pole