ABB F404 RCCB, 40A, 3+N Pole, 30mA, Type A
- RS-stocknr.:
- 176-885
- Fabrikantnummer:
- 2CCF544310E0400 - F404A-K40/0.03,2CC
- Fabrikant:
- ABB
Afbeelding representeert productcategorie
Subtotaal (1 eenheid)*
€ 376,02
(excl. BTW)
€ 454,98
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 16 maart 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 376,02 |
*prijsindicatie
- RS-stocknr.:
- 176-885
- Fabrikantnummer:
- 2CCF544310E0400 - F404A-K40/0.03,2CC
- Fabrikant:
- ABB
Datasheets
Wetgeving en compliance
Productomschrijving
- Land van herkomst:
- CH
RCCB, F404-K, short time delayed
Time-delayed SMISSLINE RCCB
With integrated input wiring
Contact position display
Upper input terminals can be used as feed
Pluggable in any position
Sensitive to AC and pulsed DC fault currents
Double-level output terminal
With integrated input wiring
Contact position display
Upper input terminals can be used as feed
Pluggable in any position
Sensitive to AC and pulsed DC fault currents
Double-level output terminal
ABB RCCB, Vibration Resistant, >5000 Cycles Mechanical Lifespan - F404 Series - 2CCF544310E0400 - F404A-K40/0.03,2CC
Keen to get a handle on electrical faults? Turn to this RCCB from ABB to maintain the balance between incoming and outgoing currents in an attached circuit. If an imbalance causes current to leak to the earthing wires, this unit will quickly cut off the power supply so you won't be in for a shock. The finger-proof terminals mean you're in safe hands when setting up the breaker. As it's vibration-resistant, you can be sure it stays grounded should things get shaky.
Features & Benefits
• Can be mounted in any position for flexibility
• Mechanical endurance of >
• Mechanical endurance of >
5000 operating cycles for long-term reliability
• Broad operating temperature range between -25°C and +55°C for safe use in challenging settings
• Broad operating temperature range between -25°C and +55°C for safe use in challenging settings
Applications
• Commercial buildings
• Packaging plants
• Lighting fixtures
• Packaging plants
• Lighting fixtures
How can I tell if this RCCB is on or off?
Thanks to the built-in contact position display which turns green if it's on and red if it's off, you can read the operating status of this RCCB at a glance.
How do I reset this RCCB?
To reset this RCCB after a fault has been cleared, simply flip the built-in toggle switch.
