Allen Bradley 1492-RCDA RCD, 25A, 1+N Pole, 30mA, Type A

Subtotaal (1 eenheid)*

€ 143,81

(excl. BTW)

€ 174,01

(incl. BTW)

Add to Basket
selecteer of typ hoeveelheid
Op voorraad
  • 11 stuk(s) klaar voor verzending
  • 7 stuk(s) klaar voor verzending vanaf een andere locatie
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks
Per stuk
1 +€ 143,81

*prijsindicatie

RS-stocknr.:
136-8584
Fabrikantnummer:
1492-RCDA2A25
Fabrikant:
Allen Bradley
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren

Merk

Allen Bradley

Circuit Breaker Type

RCD

Current Rating

25A

Number of Poles

1+N

Trip Sensitivity

30mA

Tripping Characteristics

Type A

Series

1492-RCDA

Rated AC Voltage

230 V, 400V

Mounting Style

DIN Rail Mount

Breaking Capacity at Maximum Voltage Rating

1 (Residual) kA, 10 (Short-Circuit) kA

Overall Depth

75mm

Overall Width

88mm

Terminal Contact Type

Screw

Reset Actuator Type

Toggle Switch

Overall Dimensions

35 x 88 x 75mm

Overall Length

35mm

Land van herkomst:
IT

1492 Series


Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.

Features & Benefits


2 or 4 pole versions
DIN Rail mount
Screw Terminals

Quickly detect critical errors in an electrical circuit with this residual current device (RCD) from Rockwell Automation's Allen Bradley range. This essential safety device automatically cuts an electrical supply when there's a fault to protect against fatal shocks and reduce the risk of electrical fires. Its instantaneous break time means the device responds immediately to irregular current caused by a short circuit, ground fault or locked rotor current. This ensures optimal levels of operator safety. This type-A circuit breaker is suited to AC (alternating current) industrial applications.

• Screw terminals for reliable and durable wiring
• Fast-clip device for quick and simple DIN rail mounting
• Includes a toggle switch reset actuator for simple resetting of the device
• Trip sensitivity of 30 mA to protect against current spikes and dangerous electrical shocks

Standards and Certifications


• RoHS (Restriction of Hazardous Substances)

What can cause an RCD to trip?


There are several factors that could cause an RCD to trip. These include damaged or faulty electrical wiring, incorrect current rating, weather conditions such as lightning or the presence of moisture in a circuit or appliance.