ABB F200 RCCB, 63A, 4 Pole, 30mA, 400V ac
- RS-stocknr.:
- 176-9637
- Fabrikantnummer:
- 2CSF204325R1630 F204 F-63/0,03
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 764,54
(excl. BTW)
€ 925,09
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 22 mei 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 764,54 |
*prijsindicatie
- RS-stocknr.:
- 176-9637
- Fabrikantnummer:
- 2CSF204325R1630 F204 F-63/0,03
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Circuit Breaker Type | RCCB | |
| Current Rating | 63A | |
| Number of Poles | 4 | |
| Trip Sensitivity | 30mA | |
| Voltage Rating | 400V ac | |
| Series | F200 | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Overall Depth | 85mm | |
| Overall Width | 69mm | |
| Reset Actuator Type | Toggle Switch | |
| Terminal Contact Type | Screw | |
| Overall Length | 70mm | |
| Break Time | Time Delay | |
| Mounting Style | DIN Rail Mount | |
| Special Features | Earth Fault Safety Protection | |
| Overall Dimensions | 70 x 69 x 85mm | |
| Earth Leakage Protection Type | A-APR | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Circuit Breaker Type RCCB | ||
Current Rating 63A | ||
Number of Poles 4 | ||
Trip Sensitivity 30mA | ||
Voltage Rating 400V ac | ||
Series F200 | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Overall Depth 85mm | ||
Overall Width 69mm | ||
Reset Actuator Type Toggle Switch | ||
Terminal Contact Type Screw | ||
Overall Length 70mm | ||
Break Time Time Delay | ||
Mounting Style DIN Rail Mount | ||
Special Features Earth Fault Safety Protection | ||
Overall Dimensions 70 x 69 x 85mm | ||
Earth Leakage Protection Type A-APR | ||
- Land van herkomst:
- IT
F204 Type F, RCCB in four poles with rated current 25-40-63A and sensitivity 30mA for the protection of more than one single phase circuit with a single device.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR
this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.