ABB F200 Series Residual Current Circuit Breaker, 63 A, 4-Pole, 30 mA, Type F, 1 kA 400 V ac
- RS-stocknr.:
- 176-9637
- Fabrikantnummer:
- 2CSF204325R1630 F204 F-63/0,03
- Fabrikant:
- ABB
Subtotaal (1 eenheid)*
€ 764,54
(excl. BTW)
€ 925,09
(incl. BTW)
GRATIS bezorging voor bestellingen van meer dan € 75,00
Tijdelijk niet op voorraad
- Verzending vanaf 16 juli 2026
Heeft u meer nodig? Klik op 'Controleer leverdata' voor extra voorraad en levertijden.
Aantal stuks | Per stuk |
|---|---|
| 1 + | € 764,54 |
*prijsindicatie
- RS-stocknr.:
- 176-9637
- Fabrikantnummer:
- 2CSF204325R1630 F204 F-63/0,03
- Fabrikant:
- ABB
Specificaties
Datasheets
Wetgeving en compliance
Productomschrijving
Zoek vergelijkbare producten door een of meer kenmerken te selecteren.
Alles selecteren | Attribuut | Waarde |
|---|---|---|
| Merk | ABB | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63 A | |
| Number of Poles | 4 | |
| Series | F200 | |
| Range | F200 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type F | |
| Mount Type | DIN Rail | |
| Standards/Approvals | CE, IEC EN 61008, RoHS | |
| Terminal Type | Screw | |
| Depth | 69mm | |
| Width | 70 mm | |
| Height | 85mm | |
| Breaking Capacity | 1kA | |
| Rated AC Voltage | 400 V ac | |
| Tripping Mechanism | Electromagnetic | |
| Reset Actuator Type | Toggle Switch | |
| Earth Leakage Protection Type | A-APR | |
| Alles selecteren | ||
|---|---|---|
Merk ABB | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63 A | ||
Number of Poles 4 | ||
Series F200 | ||
Range F200 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type F | ||
Mount Type DIN Rail | ||
Standards/Approvals CE, IEC EN 61008, RoHS | ||
Terminal Type Screw | ||
Depth 69mm | ||
Width 70 mm | ||
Height 85mm | ||
Breaking Capacity 1kA | ||
Rated AC Voltage 400 V ac | ||
Tripping Mechanism Electromagnetic | ||
Reset Actuator Type Toggle Switch | ||
Earth Leakage Protection Type A-APR | ||
- Land van herkomst:
- IT
F204 Type F, RCCB in four poles with rated current 25-40-63A and sensitivity 30mA for the protection of more than one single phase circuit with a single device.
Type F features at a glance:
Type F RCDs offer the same range of protection and functionality as an RCD Type A APR; this means that they detect sinusoidal AC currents as well as pulsating DC currents. In addition to this, they are also tested according to IEC/EN 62423 which foresees the application of a simulated multi-frequency residual current with appropriate coefficient associated to the each level of frequency up to 1kHz.
The intervention characteristic has a short-time delayed which prevents unwanted tripping in case pulsed leakage currents of up to ten milliseconds occur at activation of filters.
The RCDs Type F have a surge current withstand capacity of more than 3kA and can accept superimposed smooth DC residual currents of up to 10mA without affecting their standard functionality.